27830 -23/40-
A358
A359
0-I280
TY-CNL-D
1.7x2.5
A309
6-10. Assembly of A358 and 0-T51
1) Stick DT (7x8) on T51.
2) Fix 0-T51 to A358 while aligning the positioning holes
with studs.
3) Apply the epoxy resin adhesives while clipping the switch
and plate together, and leave them until they become hard.
6-11. Installation of A358 (0-T51)
1) Apply G151 to code plate of A313.
Fig.124
2) 0-I280, TY-CNL-G1.7x5.0
3) Install A358 (Apply G151 to lands) to cover, using care
that A358 (indicated by A) is set to proper position,
and then tighten TY-CNL-D1.7x2.5 and A359.
4) [CONF.]
Confirm the operation of shutter release and Preview.
5) A309, TY-CNL-D1.7x3.5 (x2)
6-12. Assembly of Flash Unit
Fig.125
1) Install 0-Q100 to Q20 as shown in Fig.126, and then install it to Q2.
2) Arrange the lead wires and trigger coil.
3) Apply silicone as shown in Fig.128.
Fig.126
Fig.128
Fig.127
4) Q1, TY-CNL-D1.7x3.0Ni (x2), TY-CNL-B1.4x3.0Ni (x2)
5) Apply L115 to the groove of Q2 (2 places).
6-13. Installation of Flash Unit
1) Pass 4 leas wires of 0-Q100 through the square hole of A301.
Fig.129
2) Install black dowel of 0-A362 (x2) to A301, and opposite side of them to Q2.
3) Insert Q7 into A301 from no groove portion side of Q7 as shown in Fig.130.
4) Q3 (Retain the flexible board as shown in Fig.130.), TY-CNL-D1.7x3.5 (x2)
5) Solder 7 lands on 0-T51.
Fig.131 Fig.130
Super-X
(Clear)
0-Q100
Q20
Green
Green
Blue
Silicone
Green
Blue
Black
Brown
The epoxy resin adhesives
A358
0-T51
A
0-A362
Q7
Q3