ULTRATEMP
®
Heat Pump Installation and User’s Guide
19
Control Panel Menu Tree Guide
(Press MENU SELECT Button)
Navigating the Menu Screens
Press the MENU SELECT button to view each screen.
While in the menu screens, if no activity is detected after 15
seconds, the main screen is displayed.
1. Pool and Spa Run Screens
Displays whether the heat pump is idle, heating or cooling if the
Pool or Spa set point is active. Displays the water temperature
set point and the actual measured water temperature.
2. Heat or Cool Mode Selection Screen
This screen is only shown on Auto Heat and Cool heat pumps.
This screen allows the operator to switch the heat pump
between heat-only, cool-only and auto heat/cool modes.
3. Heat Pump Timer Screen
This feature is an adjustable timer to allow the heat pump to
run (green LED ON) and then turn OFF (green LED OFF)
for a predetermined amount of time.
4. Relay Remote On/Off Screen
Allows the operator to turn the Relay Remote mode On and
Off. In Relay Remote mode, the heat pump is controlled by
an automation controller. The local Pool and Spa set points
are still active in this Relay Remote mode.
Note: When using
RS485 communication cable, the relay remote must be
turned off.
5. AutoSet On/Off Screen
This screen is only shown if the AutoSet mode is enabled
during factory setup; it allows the operator to turn the AutoSet
mode On and Off. AutoSet mode periodically energizes a filter
pump contactor to start a remote filter pump which allows the
heat pump to heat or cool the water as necessary.
6. Time Delay Screen
If the heat pump is waiting on any restart, pump start, or
sensing water temperature delays, this screen shows how
much delay time is left.
7. Suction Temperature Screen
Shows the suction line temperature of the refrigerant. This
screen appears if the defrost is enabled.
8. Alarm Screen
Shows if an alarm condition is present. If no alarms are present
the screen will display ALARM STATUS NONE. The control
board has the ability to store a 30 Alarm history of previous
alarms that have occurred. At the alarm status screen, press
the DOWN arrow. The first alarm will be the most recent
alarm that has occurred. Successive presses (up to 30) of
the DOWN arrow will display the alarm history in the order
of occurrence. The operator can scroll back up using the UP
button. There is an option to erase the history.
9. Auto Mode Screen
Displays whether the heat pump is in Heat only, Cool only or
Auto mode. It also displays whether the Pool or Spa set point
is active. The active set point can be switched between Pool
and Spa by using the UP and DOWN arrows.
Menu appears only if heat and cool mode is enabled
at the factory.
Menu appears only if Autoset is enabled at the factory.
Menu appears only if a delay is active.
Menu appears only if defrost is enabled in the operator menu.
MENU SELECT
MENU TREE
POOL
IDLE/HEAT/COOL
SET=__ ACT=__
SPA
IDLE/HEAT/COOL
SET=__ ACT=__
HEAT / COOL / AUTO
SET TO - H/C/A
HEAT PUMP RUNTIME
REMAINING = NONE
RELAY REMOTE
ON/OFF
AUTOSET
OVERRIDE IS ON/OFF
ALARM STATUS
RESTART / PUMP START /
SENSING WATER TEMP
DELAYS
SUCTION TEMP
ACTUAL = ___
AUTO MODE
POOL/SPA
*
**
***
****
Heat Pump
Control Panel
*
*
**
***
****
**
***
****