background image

INTELLIFLO

XF

®

 

and INTELLIPRO

XF

®

  

Variable Speed Pump Installation and User’s Guide

13

12

 

Pump Menu: Speeds 1-8

Set Speeds 1-8 in Schedule Mode

In  Schedule  mode,  Speeds  1-8  can  be  programmed 

to run a certain speed at a certain time of day. To run 

a  scheduled  speed,  press  Start/Stop. The  screen  will 
display  “Running  Schedules”  when  it  is  ready  to  run 
a  scheduled  speed.  If  Start/Stop  is  pressed  while  a 
scheduled speed is running, “Running Speed _”  will be 
displayed (see far left image).
1. 

Press 

Menu

.

2.  Use 

Up

 or 

Down

  arrows  to  scroll  to “Speed  1-8”, 

then press 

Select

.  

3.  Use 

Up

 or 

Down

 arrows 

and press 

Select

 

for the 

speed you wish to set and schedule.

4. 

Press 

Select 

(display will be highlighted) and 

scroll to “Schedule”.

5. 

Press 

Enter

.

6.  Press 

Down

 arrow (“Set Speed” will display) and 

press 

Select 

to change. Use the 

Up 

or 

Down

 

arrow to adjust speed. 

7.  Press 

Enter

 to save the new speed.

8. 

Press the 

Down

 arrow again, “Set Start Time” will 

display. 

Press 

Select 

the cursor will highlight the 

minute column. 

9.  Use the 

Up 

or 

Down

 arrow to change the time 

and the 

Left 

or

 Right

 arrow to move cursor from 

minutes to hours.

10. 

Press 

Enter

 to save the new start time setting. 

11. 

Press 

Down

 arrow - “Set Stop Time” will display. P

ress 

Select

. Repeat Steps 8-9 to set stop time.

12. 

Press 

Enter

 to save the new stop time setting. 

13. 

Press 

Start/Stop

The IntelliFloXF

® 

Variable Speed Pump will prime and 

begin to run the programmed schedule at the specified 
start time. 

When  running  in  Schedule  or  Egg  Timer  mode,  the 
countdown time (T 00:01) showing the hours and 

minutes remaining is displayed.

Note:

  The pump will not run the scheduled speeds until the 

Start/Stop

 button is pressed (LED on) to place the pump in 

Schedule mode.

Note:

 

When two speeds are scheduled during the same run 

time the pump will run the higher RPM Speed regardless of 
Speed # in use.

Note: 

The most recent command, Manual or Schedule, takes 

priority regardless of speed number RPM.

Programming Schedule for Constant Run

A speed cannot be programmed with the same start 
and stop times. To run a speed without stopping, set 

the Start time one minute after the stop time. 

Example: A single speed will run non stop if programmed 
with a Start Time of 8:00 AM and a Stop time of 7:59 AM.

Pump Menu: External Control

External Control

This function is for programming speeds that will run 

when the IntelliComm

®

 Communication Center sends it a 

command.  For example, Terminal 3 and 4 in IntelliComm 
system will correspond to External Control Program #1. 
(5 and 6 to Ext Ctrl #2). Use the External Control feature 
to program the IntelliComm system power center.

To access the External Control menu:

1.  Check that the green power LED is on.
2.  Press the 

Menu

 button. 

3.  Use 

Up

 or 

Down

 arrow to scroll to “Ext. Ctrl.”.

5.  Press 

Select

. “Program 1” is displayed.  

6. Press 

Select

 to change the speed. The “RPM” 

number will highlight. 

7. Press 

Up

 or 

Down 

arrow to change the RPM 

setting.

8.  Press 

Enter 

to save the setting. 

Note: 

To cancel any changes, press the 

Escape

 

button to exit without saving.

9.  Press 

Escape 

to return to set Program 2.

10.  Use 

Up

 or 

Down 

arrow to scroll to “Program 2”.

11.  Repeat Steps 6 through 10 to set Program 2, 3, 

and 4.

 

Setting Schedule Mode

Display During Schedule Mode

12:15p

Set Speed

Schedule

12:15p

750 RPM

T 1:05  150 WATTS

Running Speed 1

EXT CONTROL

MENU 

MENU 

SPEED 1-8

Summary of Contents for IntelliFloXF

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP...

Page 2: ...peed Pump Operating Modes Control Panel Language Operator Control Panel Menu Guide Pump Settings Pump Address Set Time AM PM or 24 Hour Clock Set Temperature Unit Screen Contrast Level Set Min Max Spe...

Page 3: ...NUAL BEFORE USING THIS PUMP THESE WARNINGSAND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMALLSUCTION OUTLETS THE USE OF UNAPPROVED C...

Page 4: ...f suction can pose a risk if a person comes within the close proximity of the suction openings A person can be seriously injured by this high level of vacuum or may become trapped and drown It is abso...

Page 5: ...ll the retainer ring with the tab features pointing away from the nut Union Adapter Installation Installing the locking union onto the pump 1 Glue the PVC union adapter fitting to the PVC pipe The ada...

Page 6: ...ump prime faster and last longer Fittings and Valves 1 Do not install 90 elbows directly into pump inlet 2 Flooded suction systems should have gate valves installed on suction and discharge pipes for...

Page 7: ...ntlyconnectedtoeither a circuit breaker 2 pole timer or 2 pole relay If AC power is supplied by a GFCI circuit breaker use a dedicated circuit breaker that has no other electrical loads 10 IMPORTANT W...

Page 8: ...or after servicing DO NOT run the pump dry If the pump is run dry the mechanical seal will be damaged and the pump will start leaking If this occurs the damaged seal must be replaced ALWAYS maintain...

Page 9: ...ls and LEDs on Key Pad Quick Clean Pump ramps up to higher RPM for vacuuming cleaning adding chemicals and after a storm for extra skimmer power LED light is on when active Time Out Pump is not runnin...

Page 10: ...Speeds 1 4 can be programmed in all three modes Speeds 5 8 can only be programmed in Schedule mode since there are no buttons on the control panel for Speeds 5 8 The default setting for Speeds 5 8 is...

Page 11: ...ion 1 min to 10 hrs Default 3 hours 1 min to 30 min Default 11 minutes Disabled Enabled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Sta...

Page 12: ...ess 4 To change the pump address press Select 5 Press Up or Down arrows to change the address number from 1 16 6 Press Enter to save To cancel any changes press Escape to exit without saving 7 Press E...

Page 13: ...on of four 4 digits Password protection can always be turned off by pressing Start Stop Password protection cannot be turned back on with Start Stop while running in manual mode Pressing Start Stop wh...

Page 14: ...is means the IntelliFloXF Variable Speed Pump will go into Password Protection mode 10 minutes after the last control panel key is pressed 8 Press Select to change time setting from 1 minute to 6 hour...

Page 15: ...o display Time 8 Press Select and use arrow keys to adjust time 9 Press Enter to save the new time setting 10 Press Escape to exit Manual Assigns a speed to one of the four Speed buttons on the contro...

Page 16: ...displayed Note The pump will not run the scheduled speeds until the Start Stop button is pressed LED on to place the pump in Schedule mode Note When two speeds are scheduled during the same run time...

Page 17: ...will be lit and ready to turn on at the next scheduled run time To access the Time Out menu 1 Check that the green power LED is on 2 Press Menu 3 Use Up or Down arrows to scroll to Features then pres...

Page 18: ...er and restart the pump Default 20 seconds Priming delay can be set from 1 second to 10 minutes If the pump does not have enough water after the automatic priming mode the pump will ramp to the Maximu...

Page 19: ...ck to page 14 for instructions on accessing the priming menu and features 1 Disable priming on automation control system 2 Disconnect the RS 485 communication cable To disable priming with an automati...

Page 20: ...4 The factory default for Anti Freeze is Enabled To disable Anti Freeze press Select to highlight Enabled 5 Press the Up arrow Disabled is displayed 6 Press Enter to save To Set Anti Freeze Speed and...

Page 21: ...r 15 100 VDC 1 mA 1 Input 50 60 Hz 5 6 Program 2 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 7 8 Program 3 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 9 10 Program 4 15 240 VAC or 15 100 VDC 1 m...

Page 22: ...o the COM port screw terminals 2 and 3 Be sure to match the color coding of the wires YELLOW to YELLOW and GREEN to GREEN The Red wire is not connected Secure the wires with the screws IntelliTouch CO...

Page 23: ...oltage raceway to the motherboard Connecting the Pump to a SunTouch Control System 4 Strip back the cable conductors 6 mm 1 4 Insert the wires into the screw terminals provided Secure the wires with t...

Page 24: ...hout water in the strainer pot Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water Opening the pump may cause serious personal injury I...

Page 25: ...s ventilation Protect against dirt 1 Protect from any foreign matter 2 Do not store or spill chemicals on or near the motor 3 Avoid sweeping or stirring up dust near the motor while it is operating 4...

Page 26: ...ith water 11 Reinstall the pump lid and locking ring see Cleaning the Pump Strainer Basket on page 20 12 Prime the system See page 4 for priming instructions Drive Assembly Removal and Installation To...

Page 27: ...rm or warning is acknowledged with the Enter button Press the Reset button to clear the alarm once the fault condition has been resolved Note The pump will not start if the impeller is rotating Power...

Page 28: ...ti spin bolt and o ring 3 Remove clean and reinstall impeller 4 Reinstall anti spin bolt and o ring Reinstall diffuser and o ring Reinstall motor and seal plate into volute Reinstall clamp band around...

Page 29: ...is open Motor runs too hot Turn power to motor off Check for proper voltage Check for proper impeller or impeller rubbing Mechanical Troubles and Noise The pump motor is running but with loud noise F...

Page 30: ...Washer U43 12SS 17 Flat Washer 072184 18 Diffuser O Ring 350336 REPLACEMENT PARTS Item No Description IntelliFloXF IntelliProXF 19 Diffuser Screw 353323 20 Diffuser 400010 21 Impeller Reverse Screw 3...

Page 31: ...mic Head in Ft of H2O Speed 1 750 rpm Speed 2 1560 rpm Speed 3 2350 rpm Speed 4 3110 rpm Max Speed 3450 rpm Pump Dimensions ANCHOR BOLT MOUNTING LOCATIONS 298 mm 11 7 in 232 mm 9 125 in 166 mm 6 5 in...

Page 32: ...abled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Start Time Set Stop Time Disabled Default Disabled Default Enabled 1 100 Default 1 1...

Page 33: ...NOTES...

Page 34: ...NOTES...

Page 35: ...NOTES...

Page 36: ...nless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentai...

Reviews: