INTELLIFLO
XF
®
and INTELLIPRO
XF
®
Variable Speed Pump Installation and User’s Guide
9
Pump Menu: Settings
Set Minimum Speed (RPM)
The minimum pump speed can be set from 450 RPM
to 1700 RPM. The default setting is 450 RPM.
1. Check that the green power LED is on.
2.
Press
Menu
.
3.
Press
Select
to select “Settings”.
4. Use the
Up
or
Down
arrows to scroll to “Set Min
Speed”.
Set Maximum Speed (RPM)
The maximum speed can be set from 1900 RPM to
3450 RPM (default is 3450). Use this setting is to set the
maximum running speed of the pump.
When the IntelliFloXF
®
Variable Speed Pump is set to
Priming “Enabled”, the pump will speed up to and run at
this speed to prime. A service professional must set the
Maximum Speed of the pump to not exceed the maximum
flow rate of the system on which it will operate.
1. Check that the green power LED is on.
2.
Press
Menu.
3.
Press
Select
to select “Settings”.
4. Use the
Up
or
Down
arrows to scroll to “Set Max
Speed”.
5.
Press
Select
to change. The cursor will appear in
the first number column (ones).
6. Press
Up
or
Down
arrows to change the maximum
speed setting from 1900 to 3450 RPM.
7. Press
Enter
. Press
Escape
to exit. To cancel, press
the
Escape
to exit without saving.
Password Protection
The default setting for password protection is disabled.
When this feature is enabled, the pump display will
prompt for the password before allowing access to the
control panel and buttons.
The entered password is any combination of four (4)
digits.
•
Password protection can always be turned off by
pressing
Start/Stop
.
•
Password protection cannot be turned back on with
Start/Stop
while running in manual mode.
•
Pressing
Start/Stop
when the pump is off will return
it back to the Running Cycles Mode and run at
the next scheduled run time. If the present time is
within the scheduled run time, the pump will run the
scheduled speed.
•
All functions including programming are disabled in
Password Protection Mode.
•
Screen will read “Enter Password” if any button other
than the
Start/Stop
button is pressed.
•
Key icon displayed in the upper left side of the
screen when Password Protection is on.
MENU
SETTINGS
12:15
750 RPM
Actual Speed
Running Speed 1
Password
Protection
Enabled
Language
To access the language menu:
1. Check that the green power LED is on.
2.
Press the
Menu
button. “Settings” is displayed.
3.
Press the
Select
button. “Pump Address” is displayed.
4. Use the
Up
or
Down
arrow button to scroll to
“Language”.
5.
Press the
Select
button to access the language menu.
6. Press
Select
to highlight current Language in use.
7. Press the
Enter
button to select the desired language
for the control panel. To cancel any changes, press
the
Escape
button to exit edit mode without saving.
8.
Press the
Escape
button to exit.
5.
Press
Select
to change the setting. The cursor
will appear in the first number column.
6. Press the
Up
or
Down
arrows to change the
minimum speed setting from 450 to 1700 RPM.
7. Press
Enter
to save. To cancel, press
Escape
to exit edit mode without saving.
8.
Press
Escape
to exit.
The Maximum Flow rate setting should be set so the
system never operates at or above 25” of Hg vacuum.