background image

INTELLIFLO

XF

®

 

and INTELLIPRO

XF

®

  

Variable Speed Pump Installation and User’s Guide

5

4

 

OPERATING THE PUMP

Follow the steps below to prime the pump for start up:

1.  Press 

Start/Stop 

to stop the pump. Disconnect the  

 

pump main power supply and communication cable.

2.  Close all gate valves in suction and discharge    
 

pipes. Relieve all pressure from the system. 

3.  Remove the pump lid and locking ring. 
4.  Fill the pump strainer pot with water.
5.  Reassemble the pump lid and locking ring onto the  

 

strainer basket. The pump is now ready to prime.

6.  Open the filter air relief valve and stand clear of    
 

the filter.

7.  Connect power to the pump. Be sure green power  

 

light is on. 

8.  Press 

Start/Stop 

to start the pump. The pump will  

 

enter into priming mode (if enabled) and speed up  

 

to the maximum speed set in the pump menu 

 settings. 

9.  When water comes out of the filter air relief valve,  

 

close the valve. The system should now be free of  

 

air and recirculating water to and from the pool.

10.  Do  not  allow  your  pump  to  run  longer  than  30 

minutes  time  without  developing  full  flow.  If  the 
pump does not prime, check your priming settings 
on  the  control  panel  or  see  the  “Troubleshooting” 
section on pages 24-25.

Priming Features 

The default priming setting is ENABLED. 

The pump also allows you to set the following from 
the operator control panel: 

• 

Maximum priming time

• 

Maximum and Minimum speed

• 

Priming sensitivity (1-100%)

• 

Priming delay 

Set up instructions on page 14.

Priming the Pump

Prime the pump before starting the pump for the first time. 

To avoid permanent damage to the pump, remove the lid 

and fill the basket with water. The pump basket must be 
filled with water before initial start up or after servicing. 

DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. 

If this occurs, the damaged seal must be replaced.  ALWAYS maintain proper water level in your pool (half way up 

skimmer opening). If the water level falls below the skimmer opening, the pump will draw air through the skimmer, 

losing the prime and causing the pump to run dry, resulting in a damaged seal. Continued operation in this manner 

could cause a loss of pressure, resulting in damage to the pump case, impeller and seal and may cause property 

damage and personal injury.

Do not add chemicals to the system directly in 
front of pump suction. Adding undiluted chemicals 
may damage the pump and will void the warranty.
This is a variable speed pump. Typically the 
lower speeds are used for filtration and heating. 
The higher speeds can be used for spa jets, 
water features, and priming.

This pump is shipped with Priming mode ENABLED. Unless the Priming settings are changed in the menu, 

be aware 

that the pump will speed up to the maximum speed when the pump is powered on for the first time, and the 

start/stop button is pressed. To change the maximum speed of the pump, refer to page 9. 
Before turning the pump ON, be sure the following conditions are met: 

1. Open filter air relief valve. 

2. Open valves. 

3. Pool return is completely open and clear of any blockages. 

4. Water in the pump basket.

5. Stand clear of the filter or other pressurized vessels.

Lid

Locking Ring

Top View

Volute

NOTE: Speed 1 is the default filtration speed. When setting up the IntelliFloXF

® 

Variable Speed Pump, the user must set the 

pump’s internal clock and establish an operation schedule by following the steps in this manual. Please refer to user’s guide 

sections: ‘Set Time’ (page 8) and ‘Set Speeds 1-8 in Schedule Mode’ (page 12) to schedule a time to run the pump.

Summary of Contents for IntelliFloXF

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP...

Page 2: ...peed Pump Operating Modes Control Panel Language Operator Control Panel Menu Guide Pump Settings Pump Address Set Time AM PM or 24 Hour Clock Set Temperature Unit Screen Contrast Level Set Min Max Spe...

Page 3: ...NUAL BEFORE USING THIS PUMP THESE WARNINGSAND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMALLSUCTION OUTLETS THE USE OF UNAPPROVED C...

Page 4: ...f suction can pose a risk if a person comes within the close proximity of the suction openings A person can be seriously injured by this high level of vacuum or may become trapped and drown It is abso...

Page 5: ...ll the retainer ring with the tab features pointing away from the nut Union Adapter Installation Installing the locking union onto the pump 1 Glue the PVC union adapter fitting to the PVC pipe The ada...

Page 6: ...ump prime faster and last longer Fittings and Valves 1 Do not install 90 elbows directly into pump inlet 2 Flooded suction systems should have gate valves installed on suction and discharge pipes for...

Page 7: ...ntlyconnectedtoeither a circuit breaker 2 pole timer or 2 pole relay If AC power is supplied by a GFCI circuit breaker use a dedicated circuit breaker that has no other electrical loads 10 IMPORTANT W...

Page 8: ...or after servicing DO NOT run the pump dry If the pump is run dry the mechanical seal will be damaged and the pump will start leaking If this occurs the damaged seal must be replaced ALWAYS maintain...

Page 9: ...ls and LEDs on Key Pad Quick Clean Pump ramps up to higher RPM for vacuuming cleaning adding chemicals and after a storm for extra skimmer power LED light is on when active Time Out Pump is not runnin...

Page 10: ...Speeds 1 4 can be programmed in all three modes Speeds 5 8 can only be programmed in Schedule mode since there are no buttons on the control panel for Speeds 5 8 The default setting for Speeds 5 8 is...

Page 11: ...ion 1 min to 10 hrs Default 3 hours 1 min to 30 min Default 11 minutes Disabled Enabled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Sta...

Page 12: ...ess 4 To change the pump address press Select 5 Press Up or Down arrows to change the address number from 1 16 6 Press Enter to save To cancel any changes press Escape to exit without saving 7 Press E...

Page 13: ...on of four 4 digits Password protection can always be turned off by pressing Start Stop Password protection cannot be turned back on with Start Stop while running in manual mode Pressing Start Stop wh...

Page 14: ...is means the IntelliFloXF Variable Speed Pump will go into Password Protection mode 10 minutes after the last control panel key is pressed 8 Press Select to change time setting from 1 minute to 6 hour...

Page 15: ...o display Time 8 Press Select and use arrow keys to adjust time 9 Press Enter to save the new time setting 10 Press Escape to exit Manual Assigns a speed to one of the four Speed buttons on the contro...

Page 16: ...displayed Note The pump will not run the scheduled speeds until the Start Stop button is pressed LED on to place the pump in Schedule mode Note When two speeds are scheduled during the same run time...

Page 17: ...will be lit and ready to turn on at the next scheduled run time To access the Time Out menu 1 Check that the green power LED is on 2 Press Menu 3 Use Up or Down arrows to scroll to Features then pres...

Page 18: ...er and restart the pump Default 20 seconds Priming delay can be set from 1 second to 10 minutes If the pump does not have enough water after the automatic priming mode the pump will ramp to the Maximu...

Page 19: ...ck to page 14 for instructions on accessing the priming menu and features 1 Disable priming on automation control system 2 Disconnect the RS 485 communication cable To disable priming with an automati...

Page 20: ...4 The factory default for Anti Freeze is Enabled To disable Anti Freeze press Select to highlight Enabled 5 Press the Up arrow Disabled is displayed 6 Press Enter to save To Set Anti Freeze Speed and...

Page 21: ...r 15 100 VDC 1 mA 1 Input 50 60 Hz 5 6 Program 2 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 7 8 Program 3 15 240 VAC or 15 100 VDC 1 mA 1 Input 50 60 Hz 9 10 Program 4 15 240 VAC or 15 100 VDC 1 m...

Page 22: ...o the COM port screw terminals 2 and 3 Be sure to match the color coding of the wires YELLOW to YELLOW and GREEN to GREEN The Red wire is not connected Secure the wires with the screws IntelliTouch CO...

Page 23: ...oltage raceway to the motherboard Connecting the Pump to a SunTouch Control System 4 Strip back the cable conductors 6 mm 1 4 Insert the wires into the screw terminals provided Secure the wires with t...

Page 24: ...hout water in the strainer pot Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water Opening the pump may cause serious personal injury I...

Page 25: ...s ventilation Protect against dirt 1 Protect from any foreign matter 2 Do not store or spill chemicals on or near the motor 3 Avoid sweeping or stirring up dust near the motor while it is operating 4...

Page 26: ...ith water 11 Reinstall the pump lid and locking ring see Cleaning the Pump Strainer Basket on page 20 12 Prime the system See page 4 for priming instructions Drive Assembly Removal and Installation To...

Page 27: ...rm or warning is acknowledged with the Enter button Press the Reset button to clear the alarm once the fault condition has been resolved Note The pump will not start if the impeller is rotating Power...

Page 28: ...ti spin bolt and o ring 3 Remove clean and reinstall impeller 4 Reinstall anti spin bolt and o ring Reinstall diffuser and o ring Reinstall motor and seal plate into volute Reinstall clamp band around...

Page 29: ...is open Motor runs too hot Turn power to motor off Check for proper voltage Check for proper impeller or impeller rubbing Mechanical Troubles and Noise The pump motor is running but with loud noise F...

Page 30: ...Washer U43 12SS 17 Flat Washer 072184 18 Diffuser O Ring 350336 REPLACEMENT PARTS Item No Description IntelliFloXF IntelliProXF 19 Diffuser Screw 353323 20 Diffuser 400010 21 Impeller Reverse Screw 3...

Page 31: ...mic Head in Ft of H2O Speed 1 750 rpm Speed 2 1560 rpm Speed 3 2350 rpm Speed 4 3110 rpm Max Speed 3450 rpm Pump Dimensions ANCHOR BOLT MOUNTING LOCATIONS 298 mm 11 7 in 232 mm 9 125 in 166 mm 6 5 in...

Page 32: ...abled Default Enabled Speed Default 2350 RPM Speed Default 3110 RPM English Default English Schedule Set Speed Set Start Time Set Stop Time Disabled Default Disabled Default Enabled 1 100 Default 1 1...

Page 33: ...NOTES...

Page 34: ...NOTES...

Page 35: ...NOTES...

Page 36: ...nless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentai...