INTELLIFLO
XF
®
and INTELLIPRO
XF
®
Variable Speed Pump Installation and User’s Guide
7
6
Stopping and Starting the Pump
Starting the Pump
1. Be sure the IntelliFloXF
®
Variable Speed Pump is
powered on and the green power LED is on.
2. Select one of the speed buttons, then press the
Start/Stop
button (LED on) to start the pump. The
pump will go into priming mode if priming feature
is enabled.
Stopping the Pump
1. Press
Start/Stop
to stop the pump.
When servicing equipment (filters, heaters, chlorinators
etc.), disconnect the communication cable, and switch
OFF circuit breaker to remove power from the pump.
Note:
The pump can automatically restart if the
communication cable is connected.
Operating the Pump at Preset Speeds
The pump is programmed with four default speeds of
750, 1500, 2350 and 3110 RPM. Speed buttons 1-4 are
for each of the preset speeds.
1. Be sure the pump is powered on and the green
power LED is on.
2. Press the
Speed
button (1- 4) corresponding to
the desired preset speed and release quickly. The
LED above the button will turn on.
3. Press
Start/Stop
. The pump will quickly change to
the selected preset speed.
To Adjust and Save a Pump Speed
1.
While the pump is running, press the
Up
or
Down
arrow to adjust to desired speed setting.
2.
Press and hold down a
Speed
button (1-4) for three
(3) seconds to save speed to the button or press
Enter
to save the speed.
Pump Operating Modes
The pumps can be programmed in three different modes:
Manual, Schedule, and Egg Timer.
Speeds 1-4 can be programmed in all three modes.
Speeds 5-8 can only be programmed in Schedule mode
since there are no buttons on the control panel for Speeds
5-8. The default setting for Speeds 5-8 is “Disabled”.
1. Manual:
Assigns a speed to one of the four Speed
buttons on the control panel. This mode can only be
used for speeds 1-4.
To operate in Manual mode, press one of the four
speed buttons and then press Start/Stop. The pump
will run the assigned speed for that speed button.
2. Egg Timer:
Speeds 1-4 can be programmed to run
for a duration of time once a speed button is pressed.
To operate in Egg Timer mode, press a speed button
and then press Start/Stop. The pump will run that
speed for the set amount of time and then turn off.
3. Schedule:
Program speeds 1-8 start and stop at
a specific time during a 24 hour period. Speeds
programmed in Schedule mode will override any
manually selected speed (speeds set by manually
pressing any of the speed buttons on the control
panel).
Control Panel Language
The default language is English.
1. Check that the green power LED is on.
2.
Press
Menu
and press Select to select “Settings”.
3. Use the
Up
or
Down
arrows and scroll to “Language”.
4.
Press
Select
. Press
Select
again to highlight current
language in use.
5.
Press
Enter
to select the control panel language. To
cancel any changes, press
Escape
to exit without
saving.
6. Press
Escape
to exit.
Speeds 5-8 Menu Guide
Speed 5 (5-8)
Schedule
Set Speed
Set Start Time
Set Stop Time
Disabled
Default: Disabled
Speed 1 (1-4)
Manual
Schedule
Egg Timer
Set Speed - Default: MANUAL
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
Speeds 1-4 Menu Guide
LED lit
Speed
1
Speed
2
Speed
3
Speed
4