INTELLIFLO
XF
®
and INTELLIPRO
XF
®
Variable Speed Pump Installation and User’s Guide
INTELLIFLO
XF
®
and INTELLIPRO
XF
®
Variable Speed Pump Installation and User’s Guide
13
Pump Menu: Features
Quick Clean
NOTE:
Quick Clean is the only high-speed override
feature of the IntelliFloXF
®
and IntelliProXF
®
Variable Speed Pumps.
This feature can be used to ramp the pump up to a
higher RPM for vacuuming, cleaning, adding
chemicals, after a storm for extra skimming capability.
Press the
Quick Clean
button (LED on) and then
Start/Stop
to start. When the Quick Clean cycle is over,
the pump will resume regular schedules and be in
“Running Schedule” mode.
To access the Quick Clean menu:
1. Check that the green power LED is on.
2. Press
Menu
.
3. Use
Up
or
Down
arrows to scroll to “Features”,
then press
Select
.
4. Press the
Down
arrow and press
Select
for
“Quick Clean”.
7. Press
Select
to choose “Set Speed”.
8. Press
Select
to highlight the “RPM” first (ones)
column and change the speed.
9. Use
Up
or
Down
arrows to change the speed.
10. Press
Enter
to save the speed.
11. Press the
Down
arrow again, and press
Select
for “Time Duration”.
12. Press
Select
to change the time. The cursor will
highlight the minutes column.
13. Use
Up
or
Down
arrows to change the time from
1 minute to 10 hours.
14. Press
Enter
to save the time.
15. Press
Escape
to exit the menu.
Time Out
This feature can be used to allow newly glued pipe joints
time to dry before circulation of the pool water resumes.
The
Time Out feature keeps the pump from running it’s
programmed speeds.
Once Time Out is finished, the pump will be in
“Running Schedule” mode, the Start/Stop LED will be
lit and ready to turn on at the next scheduled run time.
To access the Time Out menu:
1. Check that the green power LED is on.
2. Press
Menu
.
3. Use
Up
or
Down
arrows to scroll to “Features”,
then press
Select
.
5. Press
Select
to choose “Timeout”.
6. Then press
Select
again to choose “Timeout
Duration”.
7. Press
Select
to change the time. The cursor will
highlight the minutes column.
8. Press the
Left
arrow to move cursor to the hours
column.
Time out can be set from 1 minute to 10
hours.
9. Press
Enter
to save the setting.
Note:
To cancel any changes, press
Escape
to
exit without saving.
10. Press
Escape
to exit the menu.
PRIMING
DISABLED/ENABLED
(1 min. to 30 min. hrs.) Default: 11 minutes
MAX PRIMING TIME
Disabled / Enabled - Default: Enabled
Default: Enabled
(1 - 100%) Default: 1
PRIMED SENSITIVITY
(1 second - 10 minutes) Default: 20 seconds
PRIMING DELAY
DISABLED/ENABLED
MENU
Pump Menu: Priming
The default setting for Priming is ENABLED. This
setting allows the pump to automatically detect if it is
primed for startup.
The priming feature ramps the pump to 1800 RPM and
pauses for three (3) seconds. If there is sufficient water
flow in the pump basket, the pump will go out of priming
mode and run its commanded speed.
If the water flow is not sufficient, the pump will ramp
to the “Max Speed” setting and remain for the priming
delay time (default 20 seconds). If there is sufficient
water flow in the pump basket at this time, it will go out
of priming mode and ramp to the commanded speed.
If there is still insufficient flow in the pump basket, the
pump will try to prime at the “Maximum Speed” for the
amount of time set up in the “Maximum Priming Time”
menu.
Display during priming
12:15p
1800 RPM
T 00:01 460 WATTS
Priming
Continue onto the next page for Priming Features
Pump Menu: External Control
FEATURES
MENU