Pump Menu: Priming
When the IntelliFloXF
®
Variable Speed Pump
is connected to an automation control system,
(IntelliTouch
®
, EasyTouch
®
or SunTouch
®
Control
Systems),
the priming feature on the pump cannot
be disabled by the external automation control
system only. It must also be disabled on the pump
itself.
If priming is enabled on start up, the pump responds
to its internal settings
before
responding to commands
from an automation control system.
If the pump is connected to an automation control
system and priming is not desired,
disable the
priming feature on both the pump and the
automation control system.
Refer back to page 14 for instructions on accessing
the priming menu and features.
1. Disable priming on automation control system.
2. Disconnect the RS-485 communication cable.
To disable priming with an automation system:
1. Disable the priming feature on the automation control
system at the load center or using an IntelliTouch or
EasyTouch system remote. (Refer to the automation
control system user’s guide for additional information).
2. Temporarily disconnect the RS-485 communication
cable.
3. Open the lid to the control panel to disable priming
on the pump. Press
Menu
, use the arrow buttons to
scroll and select “Priming”, then select “Disabled” (the
factory default is set to “Enabled”). Press
Escape
to
exit the menu.
4. Once priming is disabled, reinstall the RS-485
communication cable.
Disabling Priming with an Automation System
3. Disable priming on pump.
4. Reinstall the RS-485 communication cable.
P
PRIMING
MENU