INTELLIFLO
XF
®
and INTELLIPRO
XF
®
Variable Speed Pump Installation and User’s Guide
15
14
Setting Priming Features
1. Press
Menu
.
2. Use
Down
arrow to scroll to “Priming” and press
Select.
3. The factory default is set to priming “Enabled“. To
disable, press
Select
.
4. Press
Enter
if you have changed the setting - this
will save the selection.
5. Press the
Down
arrow - the screen will read “Max
Priming Time”.
6. To change from factory default, press
Select.
The
cursor will highlight.
7. Use the
Up
or
Down
arrows to change the time
from 1 minute to 30 minutes.
8. Press
Enter
to save.
11. Press the
Down
arrow - the screen will read “Primed
Sensitivity”. Default is “1”.
12. Press
Select
to change the priming sensitivity. The
cursor will highlight the number.
Pump Menu: Priming
Priming Features
Default: ENABLED
Allows
IntelliFloXF
®
Variable Speed Pump to automatically detect if pump if is primed
for startup. The pump will ramp up to 1800 RPM and pause for three (3) seconds - if
there is enough water in the basket, the pump will go out of priming mode and run the
commanded speed.
Default: 11 minutes
The maximum priming time can be set from 1 - 30 minutes. This setting is the amount of
time the pump will try to prime before it gives a priming error. If this occurs, fill the pump
basket with water and restart the pump.
Default: 20 seconds
Priming delay can be set from 1 second to 10 minutes.
If the pump does not have enough water after the automatic priming mode, the pump will
ramp to the Maximum Speed (under “Pump Settings” on page 9) and run for 20 seconds
(or for the time set).
You may need to increase the priming delay to allow the system to stabilize before the
pump starts running speeds. If pump continues to show a priming error, increasing the
priming delay time might correct this issue.
Default: 1%
Priming sensitivity can be set from 1 - 100%. 1% means the pump is the most
sensitive to sensing if pump has attained prime. Increasing % will decrease amount of
flow needed for pump to sense prime.
Increase the % if the pump clearly has water in the basket but is having trouble coming
out of priming mode. Setting this number too high can cause the pump to think it has
attained a prime when it has not.
13. Use the
Up
or
Down
arrows to change from 1% to
100%. Increasing the number makes the Priming
less sensitive.
14. Press
Enter
to save.
15. Press the
Down
arrow - the screen will read “Priming
Delay”. Default is 20 seconds.
16. Press
Select
to change the priming delay time.
17. Use the
Up
or
Down
arrows to change from 1
second to 10 minutes.
Caution:
Increasing the time causes the pump to
stay in the priming mode longer.
18. Press
Enter
to save the setting.
19. Press
Escape
to exit.
DISABLED/ENABLED
MAX PRIMING TIME
PRIMED SENSITIVITY
PRIMING DELAY
PRIMING
MENU