Page 36
NOTE: INTELLIFLO “FREEZE” PROTECTION -
If the IntelliFlo pump is on due to a freeze condition (not
switch on from a relay circuit state), and if a freeze speed/flow is set in IntelliTouch, this setting takes
priority even if the previous setting is lower than the default circuit speed. If no “freeze” protection is set,
the pump will be forced
on
at the default circuit speed/flow. Any programmed or manual operation that
actually switches on a circuit, will cause the pump to run at that speed if it is higher.
NOTE: INTELLIFLO IN “SERVICE MODE” -
The IntelliFlo pump will STOP
when EasyTouch is in ‘Service” mode.
NOTE: INTELLIFLO VF PUMPS -
If the IntelliFlo VF pump is just starting (requiring a prime) and SOLAR
is available, solar will be delayed for five (5) minutes to allow the pump to prime. This only applies for
IntelliFlo pump(s) assigned as to a “pool” pump.
Priming - System Prime Time: (0 - 5 minutes) Default 0 min.: Remember that
the average unit will prime in a short period of time because the IntelliFlo has
the ability to monitor itself to make sure it is primed. “System Prime Time” is for
systems that require high flows that priming flow can provide but it is deemed
that more time is needed to fully relieve all the air. The builder can program a
pre determined amount of time, up to 5 minutes, to aid in relieving the air from
difficult filters or complex vertical plumbing. The “System PrimeTime” should
only be used where large air traps become problems within the system. The
display will inform the user when this is engaged and when it is finished during
the priming cycle at each start up cycle.
Backwash
- Clean Filter PSI (1 - 50 psi) Default 14 PSI The average PSI setting is
between 10 PSI and 20 PSI for most pools and filters. The entered PSI value splits
the percentage meter for the filter. When the “”clean filter”” value is reached,
EasyTouch displays an alert message and the pump stops monitoring flow rates
and starts managing pressure. The value represents the change in pressure
over time from start up (system clean) to present day (system getting dirty). The
changes can come from anywhere in the system, for example clogged skimmers
or pots in pumps. Setting this parameter at a lower level will cause the alert
message to come up sooner and you will have to clean your filter (cartridge) or
backwash your filter (sand or DE) sooner.
Backwash Flow GPM (15 - 130 GPM) Default 60 GPM.
Backwash Duration (1-60 minutes) Default 5 minutes.
Rinse Time (1-60 minutes) Default 1 minute.
Vacuum
Flow GPM (15-130 GPM) Default 50 GPM
This setting sets the GPM that the pool vacuum will use.
Vacuum Time Mins. (1 - 600 minutes (10 hours) Default 10 minutes
This parameter can be set from 1 to 600 minutes. The typical setting is
10 minutes. This setting sets the amount of time you wish to run the pool
vacuum.
Status
screen: Displays current operating information: GPM, RPM, Filter
minutes, and pump communication status.
Backwash Clean
Filt : 10
Flow GPM : 60
Duration : 5
Pump Vacuum
Flow (gpm) : 50
Time (min) : 10
GPM: 73
1927 RPM 1980 W
Filter: 7
Status: NORMAL
Programming EasyTouch: IntelliFlo