5.0 - Product Operation

The Pelsue #SB-SM1 4-Arm Manway Mount is built from carbon steel & incorporates high-strength alloy  steel hardware. 

The #SB-SM1 4-Arm Manway Mount 

is specifically designed to provide a compliant mounting point for a Pelsue Model 

#FT-C70 Fall Arrest Tower. All specifications, instructions, and procedures provided within this manual or upon Pelsue 

Specification Documents are based upon and only valid for usage with a Pelsue #FT-C70 Fall Arrest Tower.  The T.A. 

Pelsue Company can not verify equipment safety and/or compliance when utilized with anything other than Pelsue- 

approved #SB-SM1 complementary products.                    

General Specifications:

  

Designed for mounting on top of a closed manway commonly found in industrial locations

    

• Minimum Mounting Bolt Diameter:  17”

    • Maximum Mounting Bolt Diameter: 40”

    • Product Weight:  43 lbs. (19.2 kg)

   

5.1 - Product Description & Capabilities

The following section will address the capabilities and the general operation of the Pelsue #SB-SM1 4-Arm Manway 

Mount. The instructions contained within this section should be adhered to each and every time the product is used.  Any 

person tasked with installing or operating the piece of equipment should be familiar with these procedures.

The load ratings presented here may super-

sede or be superseded by the capabilities 

of an installed accessory.  The rating of 

a complete fall arrest system can only be 

rated to the capabilities of its lowest-rated 

component.

! WARNING !

 - 

The user must ensure that the manway to which the #SB-SM1 is attached is 

capable of withstanding all of the loads imparted to it by the device when proof-loaded.  There 

is a limitless variety of manways and addressing each potential scenario is beyond the scope 

of this manual.  A “qualified person” must approve each attachment point.

! WARNING !

 - 

The user must ensure that all fasteners are properly secured in order to retain 

the stated compliance of the entire system.

Materials & Construction

  • Main Structure 

     - Carbon Steel

  • Hardware   

     - Grade 8 Plated Steel

Compliance & rating:

    •  Fall Arrest Tower Mounting: 

The #SB-SM1 

Base Lugs provide a compliant mounting point 

for  a  Pelsue  Model  #FT-C70  Fall Arrest  Tower 

when the tower is installed and utilized per the 

published requirements.

Features:

 

• Portable Fall Arrest Tower Base for installation on 

manways

• Independently pivoting arms and sliding blocks allow 

maximum adjustment

• Folding arms and handle for easy transportation or 

stowage

Other requirements:

 

• It is the user’s responsibility to ensure that the struc

-

ture to which the #SB-SM1 is attached is capable 

of withstanding the loads imparted to it by a proof-

loaded system in order to retain stated compliance.  

*Refer  to  the  loading  diagrams  located  within  this 

section for required information*

• The #SB-SM1 is only to be used in conjunction with 

a  Pelsue  Model  #FT-C70  Fall  Arrest  Tower,  the 

system must be employed according to the require-

ments and limitations of both the manway base and 

the fall arrest tower.

Figure #5.1b:

 #SB-SM1

Folded

Summary of Contents for 500964-001

Page 1: ... SB SM1 Fall Arrest Tower Base 4 Arm Manway Mount T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Page 2: ... 500964 001 Product Manual Model SB SM1 Fall Arrest Tower Base Revision 01 Date 03 04 2010 Page 2 Page 2 ...

Page 3: ... continuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance nat...

Page 4: ...ormation 7 2 1 Serial Number 3 0 Configuration Assembly 8 4 0 Safety 9 4 1 Warning Statement 4 2 Safety Alert Symbol 4 3 General Safety Information 4 4 Operating Safety 4 5 Maintenance Safety 4 6 New Operator Safety Information 5 0 Product Operation 12 5 1 Product Description Capabilities 5 2 Product Installation Set Up 6 0 Maintenance Inspection 16 6 1 Maintenance 6 2 Inspection 6 3 Inspection Lo...

Page 5: ...r satisfaction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service pro...

Page 6: ...e of failure T A Pelsue Company s obligation hereun der shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but not limited to consequential or incidental damages flowing from use or lack of use of product Any replacement repair modification installation or other ser...

Page 7: ...ilable for future reference and for usage as a tool in the instruction of new operators Establish a regular training program for all operators Establish a regular maintenance and inspection program to keep the equip ment in top condition This product is a part of a complete Fall Arrest system The user must read understand and follow the instruc tions contained in this manual for each component or ...

Page 8: ...ct inspect all of the components for damage If damage to any of the components is discovered DO NOT USE THE PRODUCT Alert the shipping carrier immediately of the damage to the shipment 1 Ensure that the product has been shipped with all the necessary components and is in working order Refer to Fig 3a Refer to parts list above if replacement parts are required Replacement parts can be ordered from ...

Page 9: ...rt of your safety program Be certain that everyone operating this equipment is familiar with the procedures recommended and follows safety precautions Remember most accidents can be prevented Do not risk injury or death by ignoring good safety practices System owners must give operating instructions to operators or employees before allowing them to use the equipment and at least annually thereafte...

Page 10: ...ow how to use it 5 Provide a fire extinguisher for use in case of an accident Store in a highly visible place 6 Install and properly secure all guards and shields before operating 7 Wear appropriate protective gear This list includes but is not limited to A hard hat Protective shoes with slip resistant soles Heavy gloves Protective clothing Face Protection 8 Review and follow the Pre Operation Che...

Page 11: ...anders and the area around the work site Untrained operators are not qualified to operate the equipment Many features incorporated into this equipment are the result of suggestions made by customers like you Read this manual carefully to learn how to operate install the equipment safely and as intended By following the operating instructions in conjunction with a good maintenance program your prod...

Page 12: ...cessory The rating of a complete fall arrest system can only be rated to the capabilities of its lowest rated component WARNING The user must ensure that the manway to which the SB SM1 is attached is capable of withstanding all of the loads imparted to it by the device when proof loaded There is a limitless variety of manways and addressing each potential scenario is beyond the scope of this manua...

Page 13: ...actures b Ensure that all product rating warning labels are clear and legible c Check that the arms pivot freely and that the slider blocks are able to slide throughout the arms interference of the slider blocks can be indicative of a defect d All hardware has not been damaged and is in working condition 5 1 Product Description Capabilities continued 5 2 Product Installation Set up Prior to Operat...

Page 14: ...ting base of the SB SM1 is as close to the center of the manway as possible e Tighten all hardware to standard dry torques according to the size of the mounting hardware WARNING Mounting hardware must be greater or equal to 1 2 in diameter f Check to see and ensure that the arms of the manway mount sit flush to the manway cover and all hardware is tightened 5 2 Product Installation Set up continue...

Page 15: ... systems when placed in a vertical position f Utilize the installed fall arrest tower within the limits of and according to the instructions provided within the Model FT C70 fall arrest tower s product manual Figure 5 2h SB SM1 FT C70 Completely Installed Figure 5 2f SB SM1 FT C70 Installation WARNING The FT C70 Fall Arrest Tower utilized in conjunction with the SB SM1 4 Arm Manway Mount must be i...

Page 16: ... to all threads in order to extend the working life of these components 3 Complete Inspection Perform a thorough inspection paying attention to the bullet points provided within section 6 2 Record results and keep documentation A log has been provided in section 6 3 specifically for the recording of the dates results of annual system inspections Periodic Factory Service Inspection It is recommende...

Page 17: ... If there is any uncertainty with regards to cracks contact the Pelsue service department for assistance and or recommenda tions Ensure that the sections of the device can freely move and be adjusted as intended without interference Binding or interference of any kind may be indicative of structural damage and must be cause for further inspection 4 Slider blocks Ensure that when the slider blocks ...

Page 18: ...rms Mounting Blocks Notes Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Place a check in the box if item is acceptable place an x X in the box if item requires maintenance or repair Model Number Serial Number Date Purchased SB SM1 ...

Page 19: ... sales pelsue com Prior to storage the product should be thoroughly inspected and maintained Repair or replace any worn or damaged components to prevent any unnecessary down time at the next use Follow this procedure 1 Thoroughly clean the entire unit using a mild soap on the frame and labels 2 Perform a complete inspection of the unit and document the results prior to storage 3 Ensure that the un...

Page 20: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Reviews: