#500964-001 -
Product Manual: Model #SB-SM1 Fall Arrest Tower Base
- Revision 01 - Date: 03-04-2010
Page 17
6.2 - Inspection (continued)
any other structural damage, the unit should be removed from service and returned to the factory for repair.
• Pay special attention to weld locations: look for cracks or separation at the welds. Keep in mind the nickel plat
-
ing can age and scratch, this normal finish scratching can be confused with structural cracking. If there is any
uncertainty with regards to cracks, contact the Pelsue service department for assistance and/or recommenda-
tions
• Ensure that the sections of the device can freely move and be adjusted as intended without interference. Binding
or interference of any kind may be indicative of structural damage and must be cause for further inspection.
4. Slider blocks:
Ensure that when the slider blocks are not secured, that they can be easily slid throughout the arm without any
binding. Any binding could be indicative of damage to the arms. Ensure that the slider blocks can seat within the
arm properly when the tightening bolts are secured.