60
Character line 1
Unit character 1
Unit character 2
Unit character 3
Unit character 4
Unit character 5
Character line 8
Fig.19. Field intended
for the unit at the lower line
of the LCD display.
Register
Value
n character
4400+(n-1)*8
0x1F
1
1
1
1
1
4401+(n-1)*8
0x10
1
4402+(n-1)*8
0x14
1
1
4403+(n-1)*8
0x14
1
1
4404+(n-1)*8
0x14
1
1
4405+(n-1)*8
0x17
1
1
1
1
4406+(n-1)*8
0x10
1
4407+(n-1)*8
0x1F
1
1
1
1
1
Fig.20. Method
of coding a custom unit
in a single display field.
5.5.4.2. Displaying two values with their units
PCE-P30U transducer enables displaying two different values witch
their units - displayed value at the top row of display and the second
displayed value (value of any transducer register) at the bottom row
of the display. It is possible to display both values with their units.
The displayed value unit is chosen from menu
Settings
→
Display
→
Unit
(register 4020), and the second displayed value unit is chosen
from menu
Settings
→
Display
→
Unit 2
(register 4023).
Displaying two units is only possible when on the bottom row of display is
displayed second displayed value marked with
sign.