background image

BULLETIN E-90-LS1

Model LS1 Data Logger Storage

Specifications – Installation and Operating Instructions

DWYER INSTRUMENTS, INC.   

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, ,U.S.A.     Fax: 219/872-9057

e-mail: [email protected]

Lit-By Fax: 888/891-4963 

Description 

The LoggerStor is a battery powered, hand-held instrument
that allows the user to retrieve and store up to 31 full record-
ings made with any of Dwyer’s Series LCL data loggers. The
user can then transfer the stored recordings to a PC or print
them on the spot to virtually any parallel printer without using
a PC. Each recording is individually numbered for easy track-
ing and the user can transfer the saved recordings to a PC
using the software supplied with Model LCL05. An alphanu-
meric display and structured menus provide easy, intuitive
operation.

Getting Started

Place a fresh 9V alkaline battery into the unit. Any other type of
battery will result in unsatisfactory performance and may
cause damage to the instrument. Press and hold the “ON”
button on the front panel until the opening message appears in
the display. The display will show the
instrument name and software version
number. If no display is visible, or if the
display is all black, adjust the display control until the lettering
is visible.

After a few seconds the display will
change to the opening menu. The
LoggerStor is now ready for operation. 

To Retrieve A Data Logger Recording

To  retrieve a data logger recording plug the data logger you
want to retrieve information from into the LoggerStor using the
supplied cable. The LoggerStor will
automatically recognize the logger and
indicate what type of logger it is and
the first 16 characters of the user message. The LoggerStor
records logger information into Bins. Each of the 31 Bins will
hold a full logger recording. 

This means that you can hold 31 logger recordings before you
will have to record over a previously loaded Bin. It is not neces-
sary to erase a given Bin to re-use it. Simply select the Bin you
wish to re-use and save the recording to it.

PHYSICAL DATA   

Storage Capacity: 

Full recordings from up to 31 data loggers. 

Logger Connection: 

Custom cable (included). 

Printer Connection:

Parallel printer cable (not included). 

Operating Temperature: 

32˚F to 140˚F (0˚C to 60˚C).

Storage Temperature: 

-40˚F to 170˚F (-40˚C to 76˚C). 

Power:

9 V Alkaline Battery.

Display: 

Alphanumberic LCD, 16 Characters 

2 Lines. 

Dimensions: 

5

8

 

 

3

2

 

 

1

2

 

(130mm 

 

89mm

 

38mm).

Weight: 

13 oz. (369 g). 

5.125

[130]

3.500

[89]

1.500

[38]

LoggerStor

Version 2.0

Plug Logger/PC

Or Push PRINT

Found LCL22

Dwyer LCL22 Data Logger

Press 

SET/MENU

once and the

display will indicate:

Use the 

RETRIEVE/UP ARROW

and 

PRINT/DOWN ARROW

buttons to scroll through the available Bin numbers.

The top line of the display will show
the Bin number and the bottom line of
the display will show  the first 16 char-
acters of the user message stored in the Bin. If the second line
of the display is blank, then the Bin has no information stored
in it or the user message in the logger was left blank. When you
have selected the desired bin number, press 

SET/MENU

.

The display will show:

When you push 

SET/MENU

the logger

will begin to retrieve information and
the display will indicate the progress of
the recording. After the LoggerStor
has finished retrieving the recording, it will return to the display
indicating the type of logger connected and the first 16 char-
acters of the user message. At this point you may remove the
logger and can view or print the information. You may also
connect an additional logger to retrieve if you are working on
more than one logger. 

User Arrow Keys

To select Bin  #

Select Bin #: 01

Dwyer LCL22 Data Logger

Push ENTER to Start

Other to Cancel

Retrieving Data

27%

Summary of Contents for LS1

Page 1: ...mation into Bins Each of the 31 Bins will hold a full logger recording This means that you can hold 31 logger recordings before you will have to record over a previously loaded Bin It is not neces sary to erase a given Bin to re use it Simply select the Bin you wish to re use and save the recording to it PHYSICAL DATA Storage Capacity Full recordings from up to 31 data loggers Logger Connection Cu...

Page 2: ...esired filter press SET MENU to begin viewing the recording Use RETRIEVE UP ARROW and PRINT DOWN ARROW to move through the recording samples You can exit the viewing function at any time by pressing SET MENU Example Display The LoggerStor uses a display with 16 characters by 2 lines As a result of this the information displayed when viewing a recording will be compacted to fit in the display A typ...

Page 3: ...or cannot change the user information A PC is required to do this To set a logger first plug it into the LoggerStor using the supplied cable The display will show the logger type and the first 16 char acters of the user message Press SET MENU and the display will change to the message to use the message to use the arrow keys After a short delay the display will then indicate the present sampling r...

Page 4: ... when the battery is exhausted it is strongly recommended to remove the battery to avoid damage to the LoggerStor from battery leakage USE ONLY ALKALINE BATTERIES IN THE LOGGERSTOR Substitution of a different battery can result in reduced perfor mance or permanent damage to this instrument To replace the LoggerStor s battery follow the steps below 1 Make sure the LoggerStor is OFF If you are using...