Page 49
0502 Data Register (LSB)
W
INT. value - Least significant word (See relevant table)
0503 Command Register
W
See relevant table.
1101 (*) Weight division value, channel A
R/W See relevant table.
1102 (*) Decimals, channel A
R/W
1103 (*) Load cell capacity, channel A
(MSW)
R/W INT. value - Most significant word
1104 (*)Load cell capacity, channel A
(LSW)
R/W INT. value - Least significant word
1105 (*) Load cell sensitivity, channel
A
R/W INT. value
1106 (*) Fixed tare, channel A (MSW)
R/W INT. value - Most significant word
1107 (*)Fixed tare, channel A (LSW)
R/W INT. value - Least significant word
1108 (*) Multirange 1, channel A (MSW)
R/W INT. value - Most significant word
1109 (*) Multirange 1, channel A LSW)
R/W INT. value - Least significant word
1110 (*) Multirange 2, channel A (MSW)
R/W INT. value - Most significant word
1111 (*) Multirange 2, channel A (LSW)
R/W INT. value - Least significant word
1151 (*) Weight division value, channel B
R/W See relevant table.
1152 (*) Decimals, channel B
R/W See relevant table.
1153 (*) Load cell capacity, channel B
(MSW)
R/W INT. value - Most significant word
1154 (*) Load cell capacity, channel B
(LSW)
R/W INT. value - Least significant word
1155 (*) Load cell sensitivity, channel B
R/W INT. value
1156 (*) Fixed tare, channel B (MSW)
R/W INT. value - Most significant word
1157 (*) Fixed tare, channel B (LSW)
R/W INT. value - Least significant word
1158 (*) Multirange 1, channel B (MSW)
R/W INT. value - Most significant word
1159 (*) Multirange 1, channel B LSW)
R/W INT. value - Least significant word
1160 (*) Multirange 2, channel B (MSW)
R/W INT. value - Most significant word
1161 (*) Multirange 2, channel B (LSW)
R/W INT. value - Least significant word
1201 (*) Full Scale, channel A (MSW)
R/W INT. value - Most significant word
1202 (*)Full Scale, channel A (LSW)
R/W INT. value - Least significant word
1203 (*) Weight stability, channel A
R/W See correspondence in section “weighing parameters”
1204 (*) Auto-zero upon switch-on, channel
A (MSW)
R/W INT. value - Most significant word
1205 (*)Auto-zero upon switch-on, channel
A (LSW)
R/W INT. value - Least significant word
1206 (*) Zero tracking, channel A
R/W See correspondence in section “weighing parameters”
1207 (*) Resettable divisions, channel A
R/W INT. value
1208 Filter factor
R/W See correspondence in section “weighing parameters”
1209 (*) Calibration gravity (MSW)
R/W INT. value - Most significant word
1210 (*) Calibration gravity (LSW)
R/W INT. value - Least significant word
1211 (*) Use gravity (MSW)
R/W INT. value - Most significant word
1212 (*) Use gravity (LSW)
R/W INT. value - Least significant word
1251 (*) Full Scale, channel B (MSW)
R/W INT. value - Most significant word
1252 (*) Full Scale, channel B (LSW)
R/W INT. value - Least significant word
1253 (*) Weight stability, channel B
R/W See correspondence in section “weighing parameters”
1254 (*) Auto-zero upon switch-on, channel
B (MSW)
R/W INT. value - Most significant word
1255 (*) Auto-zero upon switch-on, channel
B (LSW)
R/W INT. value - Least significant word
1256 (*) Zero tracking, channel B
R/W See correspondence in section “weighing parameters”
1257 (*) Resettable divisions, channel B
R/W INT. value
1301 Input 1 function
R/W See correspondence in section “weighing parameters”
1302 Input 2 function
R/W See correspondence in section “weighing parameters”