10. WEIGHING EXECUTION COMMAND
This command is only available in case of METRIC operation. Conditions for possible use in-
clude:
• Stable weight.
• Weight changed by at least 20 divisions (weight delta) since the last weighing performed.
• Gross weight is equal to or higher than minimum weighing (20 divisions) and lower than maximum
capacity.
• Net and gross weight are positive and not null.
Master: <Addr> “P” EOT
MC 315: <Addr> “P” <status> <net> <weighing ID> ETX <chksum> EOT
or <Addr> NAK EOT