3 • Configuring the T-DAC for operation
3. Click the System Clocking hyperlink on the 3069RC Configuration Menu to open the
System Clocking
Configuration
page (see
figure 26
).
Figure 26. System Clocking Configuration page, example 1
4. For Clock Reference select master(1).
5. For Main Reference select wan-1(1).
6. For Fallback Reference select wan-2(2).
7. Click on the
Submit Query
button.
8. Select enable(1) to enable the fallback reference clock.
9. Click the
Submit Query
button.
Example 2
Another card such as the Patton Model 6511 is the clocking master and your 3096RC is a slave. This example
assumes you will use the system clock as the main reference and WAN port #1 as the fallback reference. To
define the clocking source, do the following:
1. Connect a T1/E1 WAN line to WAN port #1 through the 3096RC’s WAN port cable.
2. Click the System Clocking hyperlink on the 3069RC Configuration Menu to open the
System Clocking
Configuration
page (see
figure 27
).
Figure 27. System Clocking Configuration page, example 2
3. For Clock Reference select slave(3).
4. For Main Reference select system(500).
5. For Fallback Reference select wan-1(1).