Initial Configuration through the RS-232 Control Port
33
Model 3095 mDSL DACS Getting Started Guide
3 • Configuring the DACS for operation
•
If you are using a E1 WAN line, you will need the following information from the telco:
-
Line Type: either E1 or E1-CRC
-
Line Coding: either HDB3 or AMI
Initial Configuration through the RS-232 Control Port
Initially you must configure the 3095’s IP address and—in rare instances—change the netmask from the
default settings.
Note
Do not connect power or the Ethernet connection to the Model 3095
at this time.
Connecting the DB9-RJ45 adapter with the included cable
Do the following:
1. Connect the DB9-RJ45 adapter to your PC’s RS-232 serial port
2. Connect the RJ45-RJ45 cable between the adapter which you installed in step 1 and the RS-232 Config
port on the rear of the Model 3095 (see figure 8 on page 26).
Setting up the HyperTerminal (or similar program) session
Do the following:
1. Open a HyperTerminal session by double-clicking on HYPERTRM.EXE.
Figure 12. Connection Description window
2. Type a connection name (e.g., 3095 Config), select an icon, then click
OK (see
figure 12
)
.