![Patton electronics 3095 Getting Started Manual Download Page 43](http://html2.mh-extra.com/html/patton-electronics/3095/3095_getting-started-manual_4061180043.webp)
Using a Web browser to complete Model 3095 configuration
43
Model 3095 mDSL DACS Getting Started Guide
3 • Configuring the DACS for operation
Figure 22. System Clocking Configuration window
3. Set the
Fallback Reference
to
internal(200)
if you have no other T1/E1 Wan links for connection to the
3095. Otherwise select the appropriate Wan port under
Fallback Reference
.
4. Click on
Submit Query
.
\
Figure 23. mDSO Port Configuration window
Activating the mDSL modems
Before data transmission can occur, the internal mDSL modems must be activated. Do the following to acti-
vate the modems:
1. Click on
mDSL
on the
Configuration Menu
.
2. If you have 16 mDSL modems, click on
Activate All Available Ports
. Otherwise, you may select one of the
four groups of mDSL modems, e.g., Activate Port 5 - 8, or you may individually select any mDSL modem
in the table. Activate an individual mDSL modem by selecting
connect(1)
in the pull-down menu under
Desired State
. After you have activated all desired modems, click on
Submit Query
.
Summary of Contents for 3095
Page 6: ...Contents Model 3095 mDSL DACS Getting Started Guide 6...
Page 12: ...Model 3095 mDSL DACS Getting Started Guide 12...
Page 69: ...69 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...