6 • Alarms
mDSL DACS Administrators’ Reference Guide
42
Displaying the alarms window
clearing, or major self-clearing alarm. Any alarm type may be disabled. (“Modify Alarms—Configuring
alarm severity levels” on page 46)
Alarm Response Outputs
Alarm Response Outputs display the current setting for handling alarm notification via the different Alarm
Response Outputs. To change the Alarm Response Outputs parameters, refer to “Alarm Parameters” on
page 44.
Relay Response (alarmRlay(1))
The relay of the Alarm Port on the rear of the chassis will be activated when a major, minor, or both major and
minor alarm is generated. The Alarm Port may also be disabled.
Minor Alarm SYSLOG Priority (minorSyslogPriority)
Sets the priority of the minor alarm SYSLOG message that will be generated upon the occurrence of a minor
alarm.
Major Alarm SYSLOG Priority (majorSyslogPriority)
Sets the priority of the major alarm SYSLOG message that will be generated upon the occurrence of a major
alarm.
Minor Alarm SNMP Trap IP [address] (minorTrapIp)
Displays the IP address of a SNMP management station for receiving the SNMP trap messages upon the
occurrence of an active minor alarm. The SNMP trap messages are sent in UDP datagrams. When the IP
address is set to 0.0.0.0, no trap messages will ever be sent.
Major Alarm SNMP Trap IP [address] (majorTrapIp)
The same function as the Minor Alarm Trap IP except for only the occurrence of active major alarms.
Temperature Threshold (boxAlarmTemperature)
An alarm will be generated when the box temperature exceeds this temperature value in degrees Celsius.
Current Box Temperature (boxTemperature)
The internal temperature in the box in degrees Celsius.
Clear All Alarms
Click on this button to clear all the alarms (that is, to reset all the alarms). This clearing action will, for all the
alarms, reset the alarm, reset Time Since Alarm to 0.00 seconds, and reset the Alarm Count to 0 (zero).
Alarms
This portion of the Alarms main window displays the alarm status table, where you can view current alarm sta-
tus, manually generate an alarm as a test, and clear the alarm time and alarm count variables.
Alarm ID (alarmDefIndex)
This identifies the alarm item by a numerical index.
Summary of Contents for 3095
Page 20: ...About this guide mDSL DACS Administrators Reference Guide 18...
Page 24: ...1 Introduction mDSL DACS Administrators Reference Guide 22 Saving HTTP HTML Object Changes...
Page 40: ...5 System History mDSL DACS Administrators Reference Guide 38 mDSL History table...
Page 56: ...7 DS0 Mapping mDSL DACS Administrators Reference Guide 54 Displaying the DS0 Mapping window...
Page 96: ...11 Filter IP mDSL DACS Administrators Reference Guide 94 Defining a filter...
Page 97: ...95 Chapter 12 Frame Relay Chapter contents Introduction 96...
Page 122: ...15 TCP mDSL DACS Administrators Reference Guide 120 TCP Details...
Page 126: ...16 UDP mDSL DACS Administrators Reference Guide 124 Introduction...
Page 132: ...17 RIP Version 2 mDSL DACS Administrators Reference Guide 130 RIP Version 2 Statistics...
Page 138: ...18 SNMP mDSL DACS Administrators Reference Guide 136 Out...
Page 150: ...19 System mDSL DACS Administrators Reference Guide 148 System Packet Holding Message Blocks...
Page 180: ...21 T1 E1 Link mDSL DACS Administrators Reference Guide 178 Far End Line Statistics Totals...
Page 190: ...24 License mDSL DACS Administrators Reference Guide 188 End User License Agreement...
Page 191: ...189 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...
Page 195: ...193 Appendix B WAN Network Module connector pin out Chapter contents Introduction 194...