19 • System
mDSL DACS Administrators’ Reference Guide
146
System—Modify window
•
canada(3)
•
europeanUnion(4)
•
france(5)
•
germany(6)
Other
This portion of the
System—Modify
window contains information described in the following sections.
System Manager (sysContact)
This SNMP variable represents the textual identification of the contact person for this managed node, together
with information on how to contact this person as defined by specification RFC1213.MIB.
Box Name (sysName)
This is “An administratively assigned name for this managed node. By convention, this is the node’s fully-qual-
ified domain name." (RFC1213.MIB)
Physical Location (sysLocation)
“The physical location of this node (e.g., ‘telephone closet, 3rd floor’).” (RFC1213.MIB)
Web Settings (boxBackgroundFlag)
The following options are available:
•
disableGraphics(0)—When this option is selected, graphics on WWW pages will not be displayed. This
results in faster page display times, but may make it more difficult to navigate WWW sites that rely heavily
on graphics.
•
enableGraphics(1)—When this option is selected, graphics on WWW pages are displayed.
•
disableWeb(2)—When this option is selected, access to the WWW pages is denied for everyone.
Monitor Privilege (boxMonitorPrivilege)
Specifies the privileges given to the monitor user. Privileges can be removed or additional write access can be
given beyond read-only access. The following options are available:
•
none(0)—The monitor user can not log in.
•
read-only(2)—This is the default setting. The monitor user can view but not change any parameters. Mon-
itor can not view passwords.
•
writeUser(18)—The monitor user can change all parameters—except passwords— under authentication,
drop-and-insert, and dial-in links.
•
writeUserlp(50)—The monitor user can change all parameters—except passwords— under authentication,
drop-and-insert, dial-in, and IP links.
•
writeUserlpWan(114)—The monitor user can change all parameters—except passwords— under authenti-
cation, drop-and-insert, dial-in, IP, T1/E1, and Frame Relay links.
•
writeUserlpWanSystem(242)—The monitor user can change all parameters—except passwords— under
authentication, drop-and-insert, dial-in, IP, T1/E1, Frame Relay, System, and System Log links.
Summary of Contents for 3095
Page 20: ...About this guide mDSL DACS Administrators Reference Guide 18...
Page 24: ...1 Introduction mDSL DACS Administrators Reference Guide 22 Saving HTTP HTML Object Changes...
Page 40: ...5 System History mDSL DACS Administrators Reference Guide 38 mDSL History table...
Page 56: ...7 DS0 Mapping mDSL DACS Administrators Reference Guide 54 Displaying the DS0 Mapping window...
Page 96: ...11 Filter IP mDSL DACS Administrators Reference Guide 94 Defining a filter...
Page 97: ...95 Chapter 12 Frame Relay Chapter contents Introduction 96...
Page 122: ...15 TCP mDSL DACS Administrators Reference Guide 120 TCP Details...
Page 126: ...16 UDP mDSL DACS Administrators Reference Guide 124 Introduction...
Page 132: ...17 RIP Version 2 mDSL DACS Administrators Reference Guide 130 RIP Version 2 Statistics...
Page 138: ...18 SNMP mDSL DACS Administrators Reference Guide 136 Out...
Page 150: ...19 System mDSL DACS Administrators Reference Guide 148 System Packet Holding Message Blocks...
Page 180: ...21 T1 E1 Link mDSL DACS Administrators Reference Guide 178 Far End Line Statistics Totals...
Page 190: ...24 License mDSL DACS Administrators Reference Guide 188 End User License Agreement...
Page 191: ...189 Appendix A Network Ports RJ 21X connector pin out Chapter contents Introduction 70...
Page 195: ...193 Appendix B WAN Network Module connector pin out Chapter contents Introduction 194...