S1-2 and S1-3:  Rate Adaptation

Switches S1-2 and S1-3 are set in combination to allow the Model

2703-X21 to adapt to terminal devices running at data rates of less than
2.048 Mbps (The network rate remains 2.048 Mbps regardless of the
terminal rate adaptation setting).  The setting you select should match
the data rate of your terminal device.

S1-2

S1-3

Setting

Off

Off

2.048 Mbps

On

Off

1.024 Mbps

Off On

512 

kbps

On

On

256 kbps

S1-4:  Loopback Test Enable

Depending upon the setting of switch S1-4 the Model 2703-X21 will

either be continually in loopback mode, or loopback mode will be
enabled  by pressing and holding the front panel switch.   Since the
front panel switch is spring loaded–it returns to “Normal” operation
when pressure is released–this DIP switch provides a way of leaving
the Model 2703-X21 in “unattended” loopback mode for remote test
purposes. 

S1-4

Setting

On

Continual “unattended” loopback mode

Off

Loopback activation by front panel switch

S1-5:  Data Inversion

The setting for switch S1-5 determines whether or not the data

stream from the local DTE is inverted within the Model 2703-X21 before
being passed to the G.703 network.  The ability to invert the data
stream may be necessary when the Model 2703-X21 is being used with
an embedded G.703 device that inverts the data on the remote end.
Normally, data inversion is not necessary.

S1-5

Setting

On

Data inverted

Off

Data not inverted

S1-6, S1-7 & S1-8 Not Used  

5

3.2  INTERNAL JUMPER SETTINGS

The Model 2703-X21’s seven jumpers are located on the PC board

inside the unit.  To access the jumpers, follow these instructions:

1.

Insert a flat head screw driver into an open slot on either side
of the case, as in Figure 3. Twist the screw driver head slightly
and the top half of the case will separate from the lower half,
as in Figure  4, below. 

2.

Remove the Network Interface Module by lifting gently upward
on it until it comes free from the Model 2703-X21 main PC
board.

3.   Slide out the Network Interface Module and locate the jumpers

on the bottom side of the board.

4.

Configure the jumpers according to the section below and
return the Network Interface Module and cover to their proper
positions.

The internal jumpers mounted on the Model 2703-X21’s PC board

(labeled LK1 - LK7) are used to configure the 75 ohm or 120 ohm
network link parameters.  Figure 5 (below) shows the location of the
Model 2703’s jumpers on the internal PC board.  

6

Figure 3.  Opening the 2703 Case with a Small Screwdriver 

Figure 4.  Opening the 2703 Case With a Small Screwdriver 

NOTE:  Revision B Firmware (or newer, Implemented 6/19/98)
has been adopted to correct signal polarity at 1.024 Mbps, 512
kbps, and 256kbps.  To operate Revision B Firmware units with
Revision A (or older) units  at one of these sub-rates, you must
invert invert the data (Switch S1-5 On.  See Below) (Firmware
revision level is printed on the label on the bottom of the unit).      

Summary of Contents for 2703-X21

Page 1: ...MODEL 2703 X21 G 703 E1 Digital Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2703 X21 C Doc 031111UC Revised 6 19 98 C E R T I F I E D An ISO 9001 Certif...

Page 2: ...quipment and receiver are on different branches 1 2 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Mate...

Page 3: ...Models 2703 X21 UI and 2703 X21 DC This section describes switch and jumper locations and explains all possible configurations 3 1 EXTERNAL DIP SWITCH SETTINGS The Model 2703 X21 s DIP switch set is l...

Page 4: ...is not necessary S1 5 Setting On Data inverted Off Data not inverted S1 6 S1 7 S1 8 Not Used 5 3 2 INTERNAL JUMPER SETTINGS The Model 2703 X21 s seven jumpers are located on the PC board inside the u...

Page 5: ...m Shield to Ground Connection This setting determines whether the shield of the 120 Ohm modular cable is connected to earth ground This connection is optional when operating in 120 Ohm balanced mode T...

Page 6: ...PLY OPTIONS The Model 2703 X21 is available with three power supply options The Standard power supply option Model 2703 X21 or 2703 X21 230 is factory configured for either 115 or 230 VAC depending on...

Page 7: ...air connection the Model 2703 X21 is equipped with dual female BNCs TX and RX for connection to a 75 ohm dual coax G 703 network interface The outer conductor of the coax cables is isolated from syste...

Page 8: ...loopback mode 13 5 3 LOOPBACK TEST LAL The Model 2703 X21 is equipped with a Local Analog Loopback LAL mode to assist in evaluating the operation of the local Model 2703 X21 Any data sent to the loca...

Page 9: ...r Sensitivity 10 dB 0dB 2 4V Power 85 265 VAC switch selectable 50 60 Hz 85 265 VAC 50 60 Hz universal input option 48 VDC option Temperature Range 0 50 C 32 122 F Altitude 0 15 000 feet Humidity 5 to...

Page 10: ...ost Office Technical Guides 2 or 26 and given permission to attach Any other usage will invalidate the approval of the Interface Module Interconnection of the Interface Module the port marked Network...

Reviews: