Switch Set S1

The configuration switches on S1 set clocking, rate adaptation,

loopback enable,  and data invert.  The default settings are
summarized in the table below.  

S1-1:  Master/Slave Clock

The setting for switch S1-1 determines whether the Model 2703-

X21 provides the master clock, or is slaved to another clock source.

S1-1

Setting

On

Model 2703-X21 is master

Off

Model 2703-X21 is slave, (clock is recovered 
from the network)

3.0  CONFIGURATION

The Model 2703-X21 is equipped with one DIP set containing eight

switches (externally accessible), as well as seven jumpers (internal).
These switches and jumpers allow configuration of clocking, data rate,
and test options. The Model 2703-X21 is also equipped with an internal
switch that allows selection of 115 or 230 VAC power inputs (Note: this
switch is not present in Models 2703-X21-UI and 2703-X21-DC).  This
section describes switch and jumper locations and explains all possible
configurations.

3.1  EXTERNAL DIP SWITCH SETTINGS

The Model 2703-X21’s DIP switch set is located on the underside

of the unit (see Figure 1, below).  Figure 2 (below), shows the
orientation of the switch set.  All possible settings for the Model 2703-
X21’s switches are presented in the summary table and descriptions on
the following pages.  If you have additional questions regarding
configuration, contact Patton Technical Support at (301) 975-1000.

3

4

Figure 2. Close up of configuration switches 

OFF

1 2 3 4 5 6 7 8

DHS-8

OFF

ON

Figure 1. Underside of Model 2703, showing external DIP switch location

S1 SUMMARY TABLE

Position

Function

Factory Default

S1-1

Clock Master/Slave

On

Master

S1-2

Rate Adaptation

Off 

S1-3

Rate Adaptation

Off

S1-4

Test Enable

Off

Front Panel

S1-5

Data Inversion

Off

Not Inverted

S1-6

Not Used

Off

N/A

S1-7

Not Used

Off

N/A

S1-8

Not Used

Off

N/A

}

2.048 Mbps

S1

1     2     3     4     5     6     7     8

O N

Summary of Contents for 2703-X21

Page 1: ...MODEL 2703 X21 G 703 E1 Digital Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2703 X21 C Doc 031111UC Revised 6 19 98 C E R T I F I E D An ISO 9001 Certif...

Page 2: ...quipment and receiver are on different branches 1 2 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Mate...

Page 3: ...Models 2703 X21 UI and 2703 X21 DC This section describes switch and jumper locations and explains all possible configurations 3 1 EXTERNAL DIP SWITCH SETTINGS The Model 2703 X21 s DIP switch set is l...

Page 4: ...is not necessary S1 5 Setting On Data inverted Off Data not inverted S1 6 S1 7 S1 8 Not Used 5 3 2 INTERNAL JUMPER SETTINGS The Model 2703 X21 s seven jumpers are located on the PC board inside the u...

Page 5: ...m Shield to Ground Connection This setting determines whether the shield of the 120 Ohm modular cable is connected to earth ground This connection is optional when operating in 120 Ohm balanced mode T...

Page 6: ...PLY OPTIONS The Model 2703 X21 is available with three power supply options The Standard power supply option Model 2703 X21 or 2703 X21 230 is factory configured for either 115 or 230 VAC depending on...

Page 7: ...air connection the Model 2703 X21 is equipped with dual female BNCs TX and RX for connection to a 75 ohm dual coax G 703 network interface The outer conductor of the coax cables is isolated from syste...

Page 8: ...loopback mode 13 5 3 LOOPBACK TEST LAL The Model 2703 X21 is equipped with a Local Analog Loopback LAL mode to assist in evaluating the operation of the local Model 2703 X21 Any data sent to the loca...

Page 9: ...r Sensitivity 10 dB 0dB 2 4V Power 85 265 VAC switch selectable 50 60 Hz 85 265 VAC 50 60 Hz universal input option 48 VDC option Temperature Range 0 50 C 32 122 F Altitude 0 15 000 feet Humidity 5 to...

Page 10: ...ost Office Technical Guides 2 or 26 and given permission to attach Any other usage will invalidate the approval of the Interface Module Interconnection of the Interface Module the port marked Network...

Reviews: