LK1:  75 Ohm Transmit Shield-to-Ground Connection

This setting determines whether the shield of the 75 Ohm (coax)

transmit cable is connected to earth ground.  This connection must be
made when operating in 75 Ohm (unbalanced) mode.  Conversely, this
connection must not be made when operating in 120 Ohm (balanced)
mode.

LK1

Setting

Strap On

75 Ohm TX Shield-to-GND Connection Made

Strap Off

75 Ohm TX Shield-to-GND Connection Broken

LK2:  75 Ohm Receive Shield-to-Ground Connection

This setting determines whether the shield of the 75 Ohm (coax)

receive cable is connected to earth ground.  This connection is optional
when operating in 75 Ohm (unbalanced) mode.  This connection must
not be made when operating in 120 Ohm (balanced) mode.

LK2

Setting

Strap On

75 Ohm RX Shield-to-GND Connection Made

Strap Off

75 Ohm RX Shield-to-GND Connection Broken

LK3:  DIP Switch S1-1 Enable

This strap is reserved for future use and must remain Off.

LK3

Setting

Strap On

Not a Valid Setting

Strap Off

Normal Setting

LK4:  120 Ohm Shield-to-Ground Connection

This setting determines whether the shield of the 120 Ohm

(modular) cable is connected to earth ground.  This connection is
optional when operating in 120 Ohm (balanced) mode.  This connection
must not be made when operating in 75 Ohm (unbalanced) mode.

LK4

Setting

Strap On

75 Ohm RX Shield-to-GND Connection Made

Strap Off

75 Ohm RX Shield-to-GND Connection Broken

The table below shows the factory default jumper settings.

Following the table are descriptions for each jumper.

NOTE: one combination of jumper settings is required for 75 ohm
operation, and another combination is required for 120 ohm
operation.  The Model 2703 is factory configured for 75 ohm
operation.) 

7

8

JUMPER SUMMARY TABLE

Jumper

Function

75 ohm 120 ohm Factory Default

LK1

75 Ohm TX Shield to GND

On

Off

On (connect)

LK2

75 Ohm RX Shield to GND

Opt.*

Off

Off (disconnect)

LK3

Reserved

Off

LK4

120 Ohm Shield to GND

Off

Opt.

Off (disconnect)

LK5

Configuration Auto-Sense 

On

Opt.

On (enabled)

LK6

75 Ohm Input Impedance

On

Off

LK7

75 Ohm Input Impedance

On

Off

}

On (75 Ohm)

*Opt. = optional setting, all others are required for proper operation

Figure 5. Jumper locations on Model 2703 PC board.

LK6
LK7
LK5
LK3

LK2

LK4
LK1

Summary of Contents for 2703-X21

Page 1: ...MODEL 2703 X21 G 703 E1 Digital Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2703 X21 C Doc 031111UC Revised 6 19 98 C E R T I F I E D An ISO 9001 Certif...

Page 2: ...quipment and receiver are on different branches 1 2 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Mate...

Page 3: ...Models 2703 X21 UI and 2703 X21 DC This section describes switch and jumper locations and explains all possible configurations 3 1 EXTERNAL DIP SWITCH SETTINGS The Model 2703 X21 s DIP switch set is l...

Page 4: ...is not necessary S1 5 Setting On Data inverted Off Data not inverted S1 6 S1 7 S1 8 Not Used 5 3 2 INTERNAL JUMPER SETTINGS The Model 2703 X21 s seven jumpers are located on the PC board inside the u...

Page 5: ...m Shield to Ground Connection This setting determines whether the shield of the 120 Ohm modular cable is connected to earth ground This connection is optional when operating in 120 Ohm balanced mode T...

Page 6: ...PLY OPTIONS The Model 2703 X21 is available with three power supply options The Standard power supply option Model 2703 X21 or 2703 X21 230 is factory configured for either 115 or 230 VAC depending on...

Page 7: ...air connection the Model 2703 X21 is equipped with dual female BNCs TX and RX for connection to a 75 ohm dual coax G 703 network interface The outer conductor of the coax cables is isolated from syste...

Page 8: ...loopback mode 13 5 3 LOOPBACK TEST LAL The Model 2703 X21 is equipped with a Local Analog Loopback LAL mode to assist in evaluating the operation of the local Model 2703 X21 Any data sent to the loca...

Page 9: ...r Sensitivity 10 dB 0dB 2 4V Power 85 265 VAC switch selectable 50 60 Hz 85 265 VAC 50 60 Hz universal input option 48 VDC option Temperature Range 0 50 C 32 122 F Altitude 0 15 000 feet Humidity 5 to...

Page 10: ...ost Office Technical Guides 2 or 26 and given permission to attach Any other usage will invalidate the approval of the Interface Module Interconnection of the Interface Module the port marked Network...

Reviews: