background image

APPENDIX C

FACTORY PARTS AND ACCESSORIES

C-1 Basic Standalone Units

The Patton Model 2703-X21 standalone digital modem is available

in three versions, depending upon the power supply installed.  The
Standard and Universal Interface versions are supplied with a power
cord, 

which must be specified in the model number when ordering.  The

DC version is supplied without power cord.  

All versions of the Model 2703-X21 are supplied without a terminal

(DTE) interface cable.  This cable may be ordered separately, or may
be supplied by the user.

Standard power supply option, 
switchable between 115 and 230 VAC ......................Model 2703-X21/*

Universal Interface power supply option,
operates in environments ranging from 
85 to 265 VAC.......................................................Model 2703-X21-UI/*

DC power supply option,
operates in 48 VDC environments, 
equipped with a 3-pin “terminal strip” 
for DC power connection .......................................Model 2703-X21-DC 

C-2 AC Power Cords

Power cord must be specified when ordering Models 2703-X21 or

2703-X21-UI.  If power cord is omitted, suffix “K” will be assigned.

Ordering Suffix (*)

Power Cord Description

A .....................................Continental Europe, CEE 7
C.....................................Australia, New Zealand
D.....................................United Kingdom
E .....................................Denmark
F .....................................France/Belgium
G.....................................India
H.....................................Israel
I ......................................Italy
J......................................Japan
K .....................................North America
L .....................................Switzerland

Example: 2703-X21-UI/D = Universal Interface w/ UK power cord.

APPENDIX D

SAFETY WARNINGS AND REQUIREMENTS

These warning notices apply to the Input Port, the port marked

“Network”.

Warning: The port marked “SAFETY WARNING: see instructions

for use” does not provide isolation sufficient to satisfy the requirements
of BS6301; apparatus connected directly to this port should either have
been approved to BS6301 or have previously been evaluated against
British Telecommunications plc (Post Office) Technical Guides 2 or 26
and given permission to attach.  Any other usage will invalidate the
approval of the Interface Module.  

Interconnection of the Interface Module (the port marked

“Network”) directly, or by way of any other apparatus, with ports on
other apparatus (marked or not so marked) may produce hazardous
conditions on the network.  Users should seek advice from a competent
engineer before such a connection is made.

The Interface Module is approved as a Host Independent Appliqué.

As such the Interface Module is only approved for use with a host, and
with host attachments, that are either type approved in their own right,
or, if supplied after March, 1989, are covered by terms of the General
Approval number NS/G/1234/J/100003.  A Host supplied under the
terms of the General Approval number NS/G/1234/J/100003 satisfies
the conditions of the paragraph above.

The Interface Module must not be modified in any way.  Any form

of modification invalidates the approval for connection, and the Patton
warranty of the unit.

The terms of the approval require that there must be a minimum

distance (5mm) between the Interface Module and any other part of the
host, including other Interface Modules.  This condition is met by default
when the Appliquè is installed in a Patton enclosure in accordance with
the instructions.  If voltages greater than 250V are present in the host ,
users should refer to a competent safety engineer for advice.

It is a condition of the approval that a copy of these user

instructions and safety warnings must be supplied with the host.
Failure to provide the Interface Module user instructions with the host
will invalidate the Appliquè approval.

Failure to install the Interface Module in accordance with these

instructions will invalidate the approval.  If you experience difficulties, or
are in any doubt, please contact your Patton representative.

17

18

Summary of Contents for 2703-X21

Page 1: ...MODEL 2703 X21 G 703 E1 Digital Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2703 X21 C Doc 031111UC Revised 6 19 98 C E R T I F I E D An ISO 9001 Certif...

Page 2: ...quipment and receiver are on different branches 1 2 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Mate...

Page 3: ...Models 2703 X21 UI and 2703 X21 DC This section describes switch and jumper locations and explains all possible configurations 3 1 EXTERNAL DIP SWITCH SETTINGS The Model 2703 X21 s DIP switch set is l...

Page 4: ...is not necessary S1 5 Setting On Data inverted Off Data not inverted S1 6 S1 7 S1 8 Not Used 5 3 2 INTERNAL JUMPER SETTINGS The Model 2703 X21 s seven jumpers are located on the PC board inside the u...

Page 5: ...m Shield to Ground Connection This setting determines whether the shield of the 120 Ohm modular cable is connected to earth ground This connection is optional when operating in 120 Ohm balanced mode T...

Page 6: ...PLY OPTIONS The Model 2703 X21 is available with three power supply options The Standard power supply option Model 2703 X21 or 2703 X21 230 is factory configured for either 115 or 230 VAC depending on...

Page 7: ...air connection the Model 2703 X21 is equipped with dual female BNCs TX and RX for connection to a 75 ohm dual coax G 703 network interface The outer conductor of the coax cables is isolated from syste...

Page 8: ...loopback mode 13 5 3 LOOPBACK TEST LAL The Model 2703 X21 is equipped with a Local Analog Loopback LAL mode to assist in evaluating the operation of the local Model 2703 X21 Any data sent to the loca...

Page 9: ...r Sensitivity 10 dB 0dB 2 4V Power 85 265 VAC switch selectable 50 60 Hz 85 265 VAC 50 60 Hz universal input option 48 VDC option Temperature Range 0 50 C 32 122 F Altitude 0 15 000 feet Humidity 5 to...

Page 10: ...ost Office Technical Guides 2 or 26 and given permission to attach Any other usage will invalidate the approval of the Interface Module Interconnection of the Interface Module the port marked Network...

Reviews: