TITLE : RP-300/310
Page -16 -
3. Connectors
3.1 Interface Connectors
Refer to Section 2.1, Interface
3.2 Electrical Characteristics
1) Input Voltage:
DC 24V ± 10%
2) Current Consumption:
Operating: Approx. 1.5 A (at ASC∥ printing)
Peak:
Approx. 10 A (at print duty 100%, For 10 seconds or
less)
Stand-by:
Approx. 0.15 A
3) Power Connector
3.3 Drawer Kick-out Connector (Modular Connector)
The pulse specified by ESC p or DLE DC4 is output to this connector.
The host can confirm the status of the input signal by using the
DLE EOT, GS a, or GS r commands.
1) Pin assignments:
Refer to Table 2.2.2
2) Connector model:
Printer side:
DAEEUN DEK-623PCB-6-B or Equivalent
User side:
6-position 6-contact (RJ12telephone jack)
< Drawer Kick-out Connector Pin Assignments >
Pin Number
Signal Name
Direction
1
Frame GND
-
2
Drawer kick-out drive signal 1
Output
3
Drawer open/close signal
Input
4
+24V
-
5
Drawer kick-out drive signal 2
Output
6
Signal GND
-
+24V is output through pin 4 when the power is turned on. However, pin 4 must by
used only for the drawer.