Press in inner
bearing
5. The Torqmotor™ housing (18) requires that
you assemble a
new
backup ring (17),
new
backup washer (25) & a
new
shaft seal (16),
with the lip facing to the inside of Torqmotor
(see figure 69A), thrust washer (14), thrust
bearing (15) and a second thrust washer
(14) in that order before pressing in the inner
housing bearing (13). SEE FIGURE 32 &
33. When these components are in place,
press
new
bearing (13) into the housing (18)
to a depth of .105/.125 inches (2.67/3.18)
below the housing wear plate contact
face. Use the opposite end of the bearing
mandrel used to press in outer bearing
(19). Reference figure 2, in the “Tools and
Materials Required for Servicing” section.
SEE FIGURE 34.
Figure 32
Figure 33
4. Invert housing (18) assembly into a soft
jawed vise with the coupling shaft bore
down, clamping against the mounting
flange. SEE FIGURE 31.
Place housing
assembly into
vise
Figure 31
Figure 34
Torqmotor™ Assembly