Parker Hannifin S.p.A. - Divisione S.B.C. “SPD” User’s Manual
32
Par. Description
Field/Unit
Def.
Type/
Notes
Pr 36
Thermal image winding
(read-only): Indicates the
estimate of the heat in the innermost coils of the motor.
If this reaches the value of 100.0 % equal to the nominal
value, b41.11 will become 1 and therefore the current
will be limited to the nominal value.
0÷100.0
[%Temp]
R
Pr 37
Thermal image of the braking resistor
(read-only):
estimate of braking resistance heat.
0÷100.0
[%Temp]
R
Pr 38
Auxiliary analogue output:
Resolution 8 bit. If b40.11
= 1, the auxiliary analogue output will be equal to38/100
.
±100.0%
[% of 4.5V]
0 R/W
Pb40
See Bit Main Block param. table
Pb41
See Bit Main Block param. table
Pb42
See Bit Main Block param. table
Pr 43
Zero encoder offset
. This parameter is used to modify
the position of the output zero trace for the zero resolver
(Pr28).
0÷4095
0 R/W
M
Pr 44
Number of pulses per revolution
: This is the number
of pulses per revolution that is used by the simulation
encoder. Maximum frequency is of 120KHz.
4÷2048
1024 R/W
M
Pr 45
Main analogue input:
Represents the value of the
main analogue input.
±32767
[1=~0.3mV]
M
Pr 46
Motor resistance:
The phase-phase resistance of the
motor.
0.1÷300.0
ohm
0 K,M
Pr 47
Motor inductance
: The phase-phase inductance of the
motor.
0.1÷500.0
[mH]
0 K
,M
Pr 48
Speed Can bus
. For further details, refer to chapter
CANBUS.
0÷7
0 M
Pb90
See Bit Main Block param. table
Pr140
Pr141
Offset Cam Programmer;
For these and following ones, refer to the Function
“Programmable output on module”
±2
15
0 M
Pr142
Pr143
Cam Programmer;
0÷2
31
0 M,L
Pr144
Pr145
Module on Can programmer output
0÷2
31
0
M,L
Pr146
Pr147
Compare values for toggle OUT1
0
M,L
Pr148
Pr149
Compare values for toggle OUT1
0
M,L