27
5.7 ProTura
®
Nanofiber Cartridge Filters
The SFC product line is designed to accept ProTura
®
Nanofiber
cartridge filters. Table 2 highlights the most common Parker
cartridge filters.
Parker will custom design cartridge filters for application-specific
systems. Contact the Parker office for additional information.
5.8 Explosion Vent Replacement
5.8.1 Dome Style Explosion Vent Replacement
CUT HAZARD - WEAR PROTECTIVE CLOTHING
1. In case of explosion, contact Parker immediately. Do not
operate or rearm the collector with another explosion vent
membrane without contacting Parker first. Serious injury
could occur.
2. Verify that the system is depressurized and safe for human
exposure before attempting to remove the old or burst
rupture panel. While loosening the capture frame bolting, take
care to avoid the sharp edges of the rupture panel as these
can cause severe cuts and/or abrasions. Remove the capture
frame and set aside.
3. After removal of the capture frame, remove the rupture panel.
This may require bending panel sections away from the frame
for frame removal. Care should be taken to avoid sharp panel
edges during this activity.
4. Dispose of the removed rupture panel in accordance with
applicable local and federal regulations.
5. Install the new rupture panel. Make sure all tags and danger
warnings are placed on the side of the explosion vent facing
out towards installer. Secure with the appropriate gasket
material, bolting and previously removed capture frame.
6. Rupture panels are not bolt torque sensitive; i.e., bolt torque
does not increase or decrease the rupture panel set pressure.
The bolt torque used should be only that which is sufficient to
create a leak-free seal.
!
CAUTION
6. Troubleshooting Guide
Use the troubleshooting guide to correct any problems that
occur with your dust collection unit. If the problem or condition
continues, contact the Parker customer service office.
All electrical/mechanical troubleshooting should be
performed by a qualified electrician/maintenance ind-
ividual familiar with Parker equipment.
Prior to troubleshooting any equipment, read the In-
stallation and Operation Manuals for each piece of
equipment to be serviced.
!
WARNING
Summary of Contents for SFC
Page 1: ...Downward Flow Cartridge Dust Collector Owner s Manual Model SFC...
Page 7: ...v Page intentionally left blank...
Page 11: ...4 FIGURE 2 SFC Typical SINGLE UNIT Installation Diagram PARKER PARKER 44 10335 0001...
Page 12: ...5 FIGURE 3 Recommended Unit Clearances 44 10337 0001...
Page 14: ...7 FIGURE 4 Single Hopper SFC 44 10309 0001...
Page 15: ...8 FIGURE 5 Multiple Hopper SFC 44 10309 0002...
Page 16: ...9 FIGURE 6 Multiple Hopper SFC 44 10309 0003...
Page 17: ...10 FIGURE 7 Multiple Modules SFC 44 10310 0001...
Page 19: ...12 FIGURE 8 SFC Pressure Gauge Installation 44 10333 0001 Rev A...
Page 20: ...13 FIGURE 9 Solenoid Wiring to Pulse Controls for 2 3 4 and 5 Tier Units...
Page 21: ...14 FIGURE 10 Pneumatic Valve Assembly 44 10332 0001...
Page 24: ...17 FIGURE 12 Abrasive Inlet Installation 44 10338 0001...
Page 27: ...20 FIGURE 16 EDAP Interconnection FIGURE 15 EDAP Installation 48 10007...
Page 30: ...23 FIGURE 17 SFC Series Door Filter Installation 44 10329 0001...
Page 37: ...30 7 Illustrated Parts FIGURE 21 SFC Series 44 10330 0001 FIGURE 22 SFC Series Explosion Vents...