Continuous Mode
The command MC selects continuous mode in which the motor runs continuously at the
specified velocity until stopped or a new velocity is programmed. Distance data is ignored.
Example:
MC
Sets continuous mode
D4000
Ignored in continuous mode
A50
Sets acceleration to 50 revs/sec
2
V20
Sets velocity to 20 revs/sec
G
Motor runs at 20 revs/sec continuously
.
.
V10
Motor speed changes to 10 revs/sec
.
.
S
Motor stops
Speed Change Mode
The MQ command allows speed changes to be made during a preset move. The speed
changes can be triggered at a set distance using the TRD command or by an input using the
TRE command.
Example:
3MQ
Set MQ mode for axis 3
3A50
Set axis 3 acceleration to 50 revs/sec
2
V15
Set velocity to 15 revs/sec
D8000
Set move distance to 8000 steps
G
Start move
TRD3000
Go to next command at D = 3000 steps
V5
Change velocity to 5 revs/sec
TRE_X1
Go to next command when Input 2 goes high
V2
Change velocity to 2 revs/sec
START
V15
V5
V2
3000 STEPS
TRIGGER
DISTANCE
I/P2
INPUT
TRIGGER
8000 STEPS
FINISH
Figure 7-1. Speed Change Mode
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for PDHX-E Series
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 15: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 68: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 92: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 98: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 101: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...