6.
Define appropriate outputs for TM8 operation using the OUTnJ command.
The TM8 is now ready for operation.
Example
The TM8 is wired as shown in Figure 3-9.
Inputs 6 to 9 are to be used as data inputs.
Input 10 is to be used as a sign input.
Outputs 3 to 5 are to be used as strobe outputs.
Set up as follows:
1.
Set
1OCON 000000 all NPN outputs
2.
Set
1ICON 00000100 bank 3 selected as pull-up
3.
Set
1IN6N
Input 6 is defined as data input.
1IN7N
Input 7 is defined as data input.
1IN8N
Input 8 is defined as data input.
1IN9N
Input 9 is defined as data input.
1IN10W
Input 10 is defined as sign bit.
4.
Set
1OUT3J
Output 3 is defined as data strobe.
1OUT4J
Output 4 is defined as data strobe.
1OUT5J
Output 5 is defined as data strobe.
The thumbwheel is now ready for use. Set the thumbwheel to the desired value and enter
the information using one of the data entry commands.
For example set the thumbwheel to +12345678
Command
Description
1DRD
Request distance data from all TM8 digits
1D
Display the distance read (D+12345678)
If you do not receive this
response, return to step
1 and retry
For further information relating to Data entry commands refer to the software section.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for PDHX-E Series
Page 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 15: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 68: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 92: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 98: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 101: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...