Motor Connections
Motor connection details can be determined from Tables 3-1 and 3-2. For example, Figure 3-
3 shows the connection required to be made to a STEBON SDT 852-150-90 motor with its
windings connected in parallel. The motor is viewed from the terminal box end with the end
plate removed.
1
2
3
4
7
8
5
6
A- A+ B+ B-
Motor casing
earth connection
Cable gland which connects
screen braid to motor casing
Figure 3-3 Connections for a STEBON Motor