Interaction of Stall Detect and Position Maintenance
If both Stall Detect and Position Maintenance are enabled and the motor is moved away from
its expected position, a stall will occur or position maintenance will attempt to bring the motor
back to position. The decision as to what happens is made as follows:
If DPE (position error) > CPE (maximum allowable position error) a stall condition
exists, if stop-on-stall is enabled the motor will stop.
If DPE (position error) > DW (deadband window), position maintenance will occur.
A value of DPE less than DW will leave the motor in its present position, a value of DPE
between DW and CPE will be corrected using position maintenance and a value of DPE the
same as or greater than CPE will cause a stall condition.