Step 3
Issue the DPC225 command (line 2, position 25)
Cursor Location
ENT ER T HE CYCL E COUNT
Once the operator has been provided with the prompting message, the actual cycle count
data is provided using the Read and Enable Numeric Keypad (VARn=NUM) or Read and
Enable Function Keys (VARn=FUN). The VARn=NUM command will enable the numeric
keypad and allow the operator to enter information. The numbers, as entered, will be
displayed at the current cursor location. Once the ENTER key is pressed, the number will be
accepted by the Controller.
Step 4
Issue the VAR1=NUM command.
Cursor Location
ENT ER T HE CYCL E COUNT
Step 5
Press a 2, followed by a 5.
Cursor Location
ENT ER T HE CYCL E COUNT
2 5
If the wrong value is entered press the C/E key and re-enter the value.
Step 6
Press the C/E key.
Cursor Location
ENT ER T HE CYCL E COUNT
2