11
Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
http://www.parker.com/tfd
Parflange ECO 25
Hydraulic Flanging and Flaring Tool
90
˚
Flanging Information for Seal-Lok Fittings
Step 10: Set Head Stop adjustment dial to recommended value
for flanging the O.D., wall thickness and material of
the tubing you are using (See Chart on page 8). Dial
settings are recommendations only and may require
adjustment to obtain desired results.
Step 11: Close swing arm against shoulder bolt.
Step 12: While keeping tube end against tube stop, rotate clamp
vise arm clockwise and securely clamp tube in die
set. Be sure to properly support long tubes during the
clamping and flanging process.
Step 13: Note: Look up the recommended flanging pressure
for the O.D., wall thickness, and tube material you are
using from the chart on page 8.
Step 14: Press and release green start button on front of machine
to start rotation of main spindle head. If head does not
rotate upon activation of motor, check electrical con-
nections and retry. Be sure to use an electrical outlet
with 110V/20A power.
Step 15: Ensure the tube is held in position and slowly actuate
the hydraulic hand pump. The flanging pin will come
forward and the tube stop will automatically rise up and
away from the tube. The pressure gauge will show a
rapid rise in pressure as the pin engages the tube end
and flanges the tube.