![Parker Parflange ECO 25 Operation Manual Download Page 5](http://html1.mh-extra.com/html/parker/parflange-eco-25/parflange-eco-25_operation-manual_3890804005.webp)
5
Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
http://www.parker.com/tfd
Parflange ECO 25
Hydraulic Flanging and Flaring Tool
ECO 25 Specifications
Height
20.5 in. (520 mm)
Width
15 in. (381 mm)
Depth
20.5 in. (520 mm)
Weight
190 lbs. (86.4 kg)
Electrical Requirements
110 Volt, 1 phase, 60Hz/20A
Motor
1.5 HP
Maximum Pump Flow
20 in.
3
/min.
Max. # Flares/Flanges per day
50
Setup Instructions
Step 1: ECO 25 Adapter
Ensure the ECO 25 Adapter (part number 6 F5OLO-S) is prop-
erly installed into the SAE straight thread port in the rear of the
ECO 25 cylinder.
Step 2: Hydraulic Pump Tee
Install the Hydraulic Pump Adapter (part number 6-6 FLO-S)
into the NPT pipe thread port in the rear of the hand-hydraulic
pump with a pipe thread sealant. Assemble the swivel end of the
Hydraulic Pump Tee (part number 6 R6LO-S) to the Hydraulic
Pump Adapter. Make sure the branch end of the Tee is oriented
upward.
Step 3: Pressure Gauge Adapter
Assemble the Pressure Gauge Adapter (part number 6 G6L-S)
onto the NPT Pipe Thread end of the pressure gauge (part
number 900044) with a pipe thread sealant.
Step 4: Pressure Gauge
Assemble the Pressure Gauge and Adapter assembly onto the
branch end of the Hydraulic Pump Tee (part number 6 R6LO-S).
Make sure to orient the front of the gauge toward the front of the
ECO 25 so it may be seen during operation.
Step 5: Hose Conversion Adapters
Install Hose Conversion Adapter #1 (part number 6 G6L-S)
onto the 1/4" male NPT threaded end (smaller end) of the Hose
Assembly (part number 910133) using a pipe thread sealant.
Then, install Hose Conversion Adapter #2 (part number 6-6
G6L-S) onto the 3/8" male NPT end (larger end) of the Hose
Assembly using a pipe thread sealant..
Step 6: Hose to Pump Tee Assembly
Assemble the swivel end of the Hose Conversion Adapter #2
(part number 6-6 G6L-S) to the remaining end of the Hydraulic
Pump Tee (part number 6 R6LO-S).
Step 7: Hose to ECO 25 Assembly
Assemble the swivel end of Hose Conversion Adapter #1
(part number 6 G6L-S) to the ECO 25 Adapter (part number 6
F5OLO-S).
Step 8: Check for Leaks
Assuring all connections are properly tightened, operate the