12
Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
http://www.parker.com/tfd
Parflange ECO 25
Hydraulic Flanging and Flaring Tool
90
˚
Flanging Information for Seal-Lok Fittings
Step 16: When the pressure gauge reaches the recommended
flanging pressure from Step 13, de-energize the hy-
draulic power supply. This will allow the flanging pin
and spindle head to retract to their original position.
Step 17: Press the red stop button on the front of the machine
to stop rotation of the main spindle head.
Step 18: Rotate clamp vise handle counter-clockwise to loosen
clamp from die set and tube and open swing arm to
expose die halves.
Step 19: Remove the top half of the die set from the die cavity
and set aside.
Step 20: Remove flanged tube from bottom half of die.