Internal Cable Replacement
Due to the continuous motion of the internal cable system, it may be necessary to replace at some
point during the positioner’s life. The internal cable assembly should provide a long service life,
Parker has tested the internal cable assembly in excess of 20 million cycles. Follow the instructions
and images to replace the internal cable assembly.
Step 1
: Remove power from the table and allow time for the base and carriage to reach room tem-
perature.
Step 2:
Remove the top cover by removing four (4) flat hex head
screws.
Step 3:
Note: After removing the top cover, take notice of the two
(2) cover spacers. If these spacers are omitted on reassembly, the
top cover will interfere with the carriage.
Step 4:
Remove the carriage PCB cover by removing two (2) flat
head screws.
Step 5:
Remove the flat cable strain relief by removing two (2) flat
head screws.
Step 6:
Disconnect the four (4) cable plugs. Use a small flat tip
screwdriver to gently unplug the plugs. Use the screwdriver to gen-
tly pry both sides of the plug.
Warning: excessive force will damage the connectors.