Mounting Surface Requirements
Proper mounting of the LX80L is essential to optimize product performance. All specifications are based
on the following conditions:
•
The positioner must be bolted down using all mounting holes provided in the base. There are two
different mounting surfaces for the LX80L, as seen below. For the
Standard Mounting Surface
,
use M4 socket head cap screws to secure the positioner with quanities “E” as listed in the chart.
To secure the positioner for the
Side Mounting Surface
, use M4 socket head cap screws with
8mm of engagement as to not damage the positioner. Use quantities “F” as listed in the chart.
Side Mounting Surface
(Side View of Positioner)
(for Single Rail Positioners Only)
MODEL
TRAVEL (mm)
8 Pole
TRAVEL (mm)
16 Pole
A B C D E
T02
150 80
325
146
N/A
N/A
6
T04
250 180
425
196
1
70
8
T06
350 280
525
246
1
70
8
T08
450 380
625
296
2
140
10
T10
550 480
725
346
3
210
12
T14
750 680
925
446
4
280
14
F
6
8
10
12
14