LX80L Series Product Manual
38
Parker Hannifin Corporation
EMN Automation - Parker
Irwin, Pennsylvania
Step 7:
Remove the cable assembly from the carriage by removing
one (1) flat head screw from the cable carrier link that is attached
to the carriage. It is necessary to lift the four (4) connectors to gain
access to the flat head screw.
Step 8:
Remove the cable side endblock from the base by removing
two (2) socket hex head cap screws.
Step 9:
Remove the flat cable strain relief, that is located near the
centerline of the base, by removing two (2) flat head screws.
Step 10:
Move the disconnected cable assembly and the carriage to
the non-cable side endblock.
Step 11:
Disconnect the cable assembly from the base by folding
the portion of the cable assembly that does not have cable carrier
links covering the cable over the portion that does have cable car-
rier links. This will expose one (1) flat head screw in the last cable
carrier link. Remove this screw
Step 13:
To assemble a new cable assembly repeat the previous steps in reverse order.
Note
: Special care needs to be taken not to pinch any of the wire when reassembling the
cable system.
Step 12:
The cable assembly can now be removed by sliding the
connector end of the cable assembly under the carriage.
Summary of Contents for LX80L
Page 56: ......