4-5
Installation
AC30 series Variable Speed Inverter
Through Panel Mount Frames D to J only
DIMENSIONS FOR THROUGH PANEL INSTALLATION
FRAMES D, E
Through panel mounting an inverter in a cubicle allows you to use a smaller cubicle because much of the heat generated by the inverter is
dissipated outside the cubicle.
Figure 4-4 Mechanical Dimensions for Through Panel - Frames D & E Inverters
Inverters
H
H1
H2
H3 *
W
W1
W2
W3
D
D1
AC30V/ AC30P
Fixings
Mounting Kits
Frame D
250 (9.8)
262 (10.3)
6 (0.2)
64 (2.51)
79 (3.1) 1.5 (0.06) 82 (3.2)
100 (3.93)
72 (2.8)
181 (7.1)
AC30D - 199 (7.83)
Use M4
fixings
LA502668
Frame E
297 (11.7) 309 (12.1)
6 (0.2)
80 (3.14) 104 (4.1) 1 (0.04)
102 (4)
125 (4.9)
72 (2.8)
181 (7.1)
AC30D - 199 (7.83)
LA502669
(* H3 only for wiring brackets) All dimensions are in millimetres (inches)