Installation
4-40
AC30 series Variable Speed Inverter
Fitting a Remote GKP
When fitting the GKP remotely to either a cubicle or panel mount it
must
be fitted to a flat surface. Maximum cable length < 3 meters.
7001-00-00 – includes the GKP only
7001-00-01 - includes the GKP, 3m connection lead and screws.
•
If ordered and supplied with the inverter the connection lead is
NOT
supplied, to order the lead the part number is LA501991U300.
Cut out details:
Gasket
Reverse side of the
GKP
GKP – Reverse side
The yellow dotted line is the cutout
detail to allow remote fitting the
connection lead, also shows screw
hole details.
Use M3 x 10 self tapping screws.
Connection lead RS232/REM OP
STA with a Steward 28A2025-OAO
connector.
All measurements in millimeter.