Setting
up Compax3
C3I12T11
102
192-120113 N08 C3I12T11 - December 2010
Resulting nominal and peak currents depending on the switching
frequency
Compax3HxxxV4 at 3*400VAC
Switching
frequency*
H050V4
H090V4
H125V4
H155V4
8kHz
I
nom
50A
rms
90A
rms
125A
rms
155A
rms
I
peak
(<5s) 75A
rms
135A
rms
187.5A
rms
232.5A
rms
16kHz
I
nom
33A
rms
75A
rms
82A
rms
100A
rms
I
peak
(<5s) 49.5A
rms
112.5A
rms
123A
rms
150A
rms
32kHz
I
nom
19A
rms
45A
rms
49A
rms
59A
rms
I
peak
(<5s) 28.5A
rms
67.5A
rms
73.5A
rms
88.5A
rms
Compax3HxxxV4 at 3*480VAC
Switching
frequency*
H050V4
H090V4
H125V4
H155V4
8kHz
I
nom
43A
rms
85A
rms
110A
rms
132A
rms
I
peak
(<5s) 64.5A
rms
127.5A
rms
165A
rms
198A
rms
16kHz
I
nom
27A
rms
70A
rms
70A
rms
84A
rms
I
peak
(<5s) 40.5A
rms
105A
rms
105A
rms
126A
rms
32kHz
I
nom
16A
rms
40A
rms
40A
rms
48A
rms
I
peak
(<5s) 24A
rms
60A
rms
60A
rms
72A
rms
The values marked with grey are the pre-set values (standard values)!
*corresponds to the frequency of the motor current
Resulting nominal and peak currents depending on the switching
frequency
Compax3MxxxD6 at 3*400VAC
Switching
frequency*
M050D6
M100D6
M150D6
M300D6
8kHz
I
nom
5A
rms
10A
rms
15A
rms
30A
rms
I
peak
(<5s) 10A
rms
20A
rms
30A
rms
60A
rms
16kHz
I
nom
3.8A
rms
7.5A
rms
10A
rms
20A
rms
I
peak
(<5s) 7.5A
rms
15A
rms
20A
rms
40A
rms
32kHz
I
nom
2.5A
rms
3.8A
rms
5A
rms
11A
rms
I
peak
(<5s) 5A
rms
7.5A
rms
10A
rms
22A
rms
Compax3MxxxD6 at 3*480VAC
Switching
frequency*
M050D6
M100D6
M150D6
M300D6
8kHz
I
nom
4A
rms
8A
rms
12.5A
rms
25A
rms
I
peak
(<5s) 8A
rms
16A
rms
25A
rms
50A
rms
16kHz
I
nom
3A
rms
5.5A
rms
8A
rms
15A
rms
I
peak
(<5s) 6A
rms
11A
rms
16A
rms
30A
rms
32kHz
I
nom
2A
rms
2.5A
rms
4A
rms
8.5A
rms
I
peak
(<5s) 4A
rms
5A
rms
8A
rms
17A
rms
The values marked with grey are the pre-set values (standard values)!
*corresponds to the frequency of the motor current