Setting up Compax3
192-120113 N08 C3I12T11 - December 2010
255
The motion range monitoring is especially important during current step
responses, as position as well as speed control are deactivated during the
measurement.
Max permitted speed
When exceeding this value, an error is triggered, the controller decelerates and
reports an error.
When measuring the velocity setpoint jerk, the maximum permitted velocity is set to
twice the step height.
Setting and automatic start of the oscilloscope:
After pressing "accept entries", the parameters of the oscilloscope (such as
scanning time and the assignment of the individual channels) are automatically set
to default values according to the respective step value.
When starting the step function, the oscilloscope is automatically started.
Start of the measurement
The start of the step function is made with the aid of the highlighted button.