Parker EME
Compax3 device description
192-120113 N08 C3I12T11 - December 2010
51
Motor holding brake output
Motor holding brake output
Compax3
Voltage range
21 – 27VDC
Maximum output current (short circuit
proof)
1.6A
Attention - Please wire the motor holding brake!
Connect the brake only on motors which have a holding brake! Otherwise make no
brake connections at all.
Requirements cables for motor holding brake
If a motor holding brake is present,
one cable
of the motor holding brake must be
fed on the device side through the toroidal core ferrite provided as accessory
ZBH0x/xx (63
Ω
@1MHz, di=5.1mm), in order to ensure error-free switching on
and off of the motor holding brake.
3.5.7.1
Measurement of the motor temperature of Compax3M
(axis controller)
Connector X15
The acquisition of the motor temperature by the axis controller can either take
place via the connection of X15 (Tmot) or via the feedback cable and the
corresponding connection on X13 PIN10.
Pin
Description
1
+5V
2
Sensor
The temperature acquisition on X15 Tmot can not be connected at the same
time as X13 Pin 10.
3.5.8.
Safety technology option for Compax3M (axis controller)
Connector X14
Pin
Description
1
STO1/
+24VDC
2
STO-GND
GND
3
STO2/
+24VDC
4
STO-GND
GND
Note!
If the Compax3M axis controller features a safety option, these connections must
also be wired, otherwise it is not possible to set up the axis.