![Parker ACR7000 Series User Manual Download Page 42](http://html2.mh-extra.com/html/parker/acr7000-series/acr7000-series_user-manual_3846060042.webp)
ELECTRICAL INSTALLATION
42
ACR7000 Controller Installation Guide
Analog Input Specifications
Description
Input Voltage
15-bit A/D converter, ±10 VDC;
bipolar range selectable
ADC GAIN command;
±10V (default), ±5V, ±2.5V, ±1.25V
Voltage Limit
±15 VDC (referenced to AGND)
Input Current (worst case load)
±160 µA
Fault Tolerance
±16.5V
Input Impedance
10
13
Ω
Sample Rate* (8 inputs)
86.5 µs