![Parker ACR7000 Series User Manual Download Page 38](http://html2.mh-extra.com/html/parker/acr7000-series/acr7000-series_user-manual_3846060038.webp)
ELECTRICAL INSTALLATION
38
ACR7000 Controller Installation Guide
Internal Encoder 8 Connections
The following figure shows a schematic diagram of the internal connections for the Encoder 8 connector.
Encoder Inputs Specifications
Description
Min Typical
Max
Units
Common Mode Range
-7
+7
V
Current—Encoder
250
mA
Current—Hall
250
mA
Differential Threshold Voltage
-200
+200
mV
Differential Termination Impedance
120
ohms
Thermal Switch Current
2
mA
Thermal Switch Voltage Maximum (supplied)
15
V
Encoder Input Frequency
(pre-quadrature)
2.5
MHz