![Parker ACR7000 Series User Manual Download Page 26](http://html2.mh-extra.com/html/parker/acr7000-series/acr7000-series_user-manual_3846060026.webp)
ELECTRICAL INSTALLATION
26
ACR7000 Controller Installation Guide
Axis Connector Power Source
Each Axis (and Auxiliary Encoder) connector has a n5 VDC power source to aid application installations.
The power source typically is used to power:
•
An external encoder
•
Optical inputs and/or outputs between the ACR7000 and an external drive
Description
Min
Max
Units
Continuous current, +5V
--
150
1
mA
Trip current, +5V
700
1200
mA
Voltage tolerance from +5V (@ 150 mA or less)
4.9
5.5
VDC
1. Maximum current draw per Axis/Encoder Connector is 250 mA, not to exceed a combined
1500 mA for eight axis connectors and two auxiliary encoder connectors.
Note:
All parameters are at the connector pin.
Equivalent Circuit for Axis Power Source
Axis Connector Fuse
The Axis connector has a +5V voltage source for powering an encoder and/or drive I/O, and includes a fuse, as
shown in Figure 8 above. In the event the +5V source shorts to ground, the internal reset-able fuse disables the
+5V source. When the short-circuit condition is removed and the fuse cools, the fuse automatically resets.
Summary of Contents for ACR7000 Series
Page 1: ...Effective September 2020 Document Number 88 033593 01A User Guide ACR7000 Controller...
Page 9: ...INTRODUCTION ACR7000 Controller Installation Guide 9 CHAPTER 1 Introduction...
Page 43: ......
Page 44: ...COMMUNICATIONS 44 ACR7000 Controller Installation Guide CHAPTER 4 Communications...
Page 51: ......
Page 52: ...BASIC OPERATION 52 ACR7000 Controller Installation Guide CHAPTER 5 Basic Operation...
Page 58: ...APPENDIX A 58 ACR7000 Controller Installation Guide Appendix A Accessories...