![Parker ACR7000 Series User Manual Download Page 31](http://html2.mh-extra.com/html/parker/acr7000-series/acr7000-series_user-manual_3846060031.webp)
ELECTRICAL INSTALLATION
ACR7000 Controller Controller Installation Guide
31
Encoder Signal Assignments
Mode
Axis Connector Signal
Supported Features
Encoder
CHA
Encoder
CHB
Position
Capture
1
Quadrature
CHA
CHB
Yes
Step and
Direction
STEP
DIR
Yes
CW and CCW
CW
CCW
Yes
SSI
SCLK
SDATA
No
1. For more information on position capture, refer to the
INTCAP
command in
Online Help System in Parker Motion Manager software
Encoder Electrical/Timing Characteristics
Description
Min
Max
Units
Pre-Quadrature frequency
0
5.0
MHz
Post-Quadrature frequency
0
20.0
MHz
Duty cycle (pre-
quad frequency ≤ 2.5 MHz)
30
70
%
Duty cycle (pre-quad frequency > 2.5 MHz)
40
60
%
Receiver Differential Threshold, V
TH
−
200
+200
mV
Common mode range, V
CM
−
10
13.2
VDC
Note:
All parameters are at the connector pin.
Encoder Circuit Schematic
Summary of Contents for ACR7000 Series
Page 1: ...Effective September 2020 Document Number 88 033593 01A User Guide ACR7000 Controller...
Page 9: ...INTRODUCTION ACR7000 Controller Installation Guide 9 CHAPTER 1 Introduction...
Page 43: ......
Page 44: ...COMMUNICATIONS 44 ACR7000 Controller Installation Guide CHAPTER 4 Communications...
Page 51: ......
Page 52: ...BASIC OPERATION 52 ACR7000 Controller Installation Guide CHAPTER 5 Basic Operation...
Page 58: ...APPENDIX A 58 ACR7000 Controller Installation Guide Appendix A Accessories...