E-37
Technical Specifications
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
Electrical Ratings (Servo): 890SD Frame F, 500V
Power Supply = 380-460V ±10%, 50/60Hz
±
5%
Motor power, output current and input current must not be exceeded under steady state operating conditions. Input
currents listed at 500Vac 50Hz for kW ratings.
500V unit full power ratings are only available at 500V. The unit can be operated between 380-500V supply
voltage with reduced output power below 500V.
Model Number
(Europe)
Catalog Number
(North America)
Motor
Power
Output
Current
(A)
(note 1)
AC Input
Current
(A)
Heatsink
Power
Loss (W)
Total
Power
Loss
(W)
Maximum
Switching
Frequency
(kHz)
Input
Bridge I
2
t
(A
2
s)
FRAME F :
Prospective short circuit current 18kA.
Quadratic Torque
Output Overload Motoring 110% for 60s (PMAC mode)
890SD-533105F...
75kW
93
118
1200
1500
4
100,000
-
890SD-533145F...
90kW
118
140
1340
1780
4
100,000
-
890SD-533156F...
110kW 135
166
1670
2180
4
100,000
-
Note 1:
Up to the highest supply voltage that maintains shaft power less than the product power rating, for a typical
induction motor. Derated for operation above this supply voltage.